SM-SX100
– 58 –
34, 35
SLAVE
Input with pull-up resistor
Mode setting of BCKO, LRCO terminal. H: Output terminal is selected. (Slave mode)
L: Input terminal is selected. (Master mode)
36*,37* THRUN
Input with pull-up resistor
Through mode setting of DOUT
H: Normal mode, L: Through mode
38
OCKSL
Input with pull-up resistor
System clock on the output side (OCLK) selection. H: 384fs, L: 256fs
39
OCLK
Input
Output system clock input
40
LRCO
Input/Output
Word clock output/input on the output side (fso)
Output/input mode is set from the slave terminal.
41, 42
BCKO
Input/Output
Bit clock output/input on the output side
Output/input mode is set from the slave terminal.
43, 44
DOUT
Output
Data output
Pin No.
Port Name
Input/Output
In this unit, the terminal with asterisk mark (*) is (open) terminal which is not connected to the outside.
Function
IC806 VHiSM5844AF-1: Sampling Rate Converter (SM5844AF) (2/2)
Note 1: "fsi" means the word clock (LRCI) on the input side, and "fso" means the work clock (LRCO) on the output side.
Note 2: When H level is set, "open" is also applicable.
Note 3: When the terminal of plural terminal Nos. for the same terminal name is used, it does not matter whether either or both
terminals are connected.
Figure 58 BLOCK DIAGRAM OF IC
MCOM
MDT/FSI1
MCK/FSI2
MLEN/DEEM
ICLK
ICKSL
LRCI
RSTN
TST1N
TST2N
OW18N
OW20N
IISN
SLAVE
OCLK
OCKSL
THRUN
DMUTE
LRCO
BCKO
DOUT
STATE
IFM1
IFM2
BCKI
DI
MODE
De-emphasis
Attenuator Setting
Division on
the Input Side
Input Timing
Controller
Filter Characteristics
Selection
Output Practice
Timing Controller
Output Format
Controller
Clock Selection on the
Output Side
Dither
Division on the
Output Side
Mute
Generation
Direct Mute
Through Mode Switch
LRCI
BCKI
DI
Output Data
Interface
Output Operation
Interpolation
Filter Operation
Attenuator
Operation Section
De-emphasis
Operation
Input Data
Interface
16
17
18
19
20
6
7
5
30
31
28
29
22
21
24
23
25
26
34
35
39
38
36
37
14
15
40
41 42
43 44
27
2
1
4
3
11 10
8
9