![Sharp SJ-RM320TB Скачать руководство пользователя страница 27](http://html.mh-extra.com/html/sharp/sj-rm320tb/sj-rm320tb_service-manual_368459027.webp)
SJ-WS320T-S
27
YES
NO
.08 / .67
(Fan motor system diagnosis)
Fan motor
rotates?
Check cause of defrosting
failure
· Dislocation of fan
· Check door packing
· Installation of E.V. cover Assy
· Defective seal
[6]
Replace Display PWB Ass'y.
.12
(Display PWB system diagnosis)
NO
NO
YES
CN4 on the main PWB is positively
engaged?
YES
[8]
Replace Plasmacluster.
(Plasmacluster system diagnosis)
NO
NO
YES
and of CN5 on the main PWB
are positively engaged? (DC 14.5V)
(Closed the refrigerating room door)
YES
and of 6P connector on R c-box
Assy are positively engaged?
Under compressor operating,
close the door switch
Replace Fan motor.
Fan locked ?
Check position of fan.
3P connector to the Display PWB
is positively engaged?
YES
.11 / .73
[7]
NO
Replace main PWB
The fuse in the circuit
of fan motor may have
blown out.
Insert connector.
Insert connector.