![Sharp SJ-RM320TB Скачать руководство пользователя страница 25](http://html.mh-extra.com/html/sharp/sj-rm320tb/sj-rm320tb_service-manual_368459025.webp)
SJ-WS320T-S
25
6. Correspondence method
• Isn’t there any problem with the
door packing?
• Isn’t there any problem with the
installation condition?
(High temperature, Direct
sunlight, Installation space, etc.)
Remedy the problem.
Power OFF
Power OFF
Replace F-thermistor.
NG?
NG?
(F-thermistor system diagnosis)
(R-thermistor system diagnosis)
NO
NO
YES
YES
Remove 6
P
connector from E.
V
.
cover Assy and measure the
thermistor resistance between
and .
Replace main PWB.
NG?
NG?
NO
NO
YES
YES
Remove
2
P connector from left
side R room lamp Assy and
measure the thermistor
resistance between
and .
.01 / .61 / .75
.02 / .62 / .76
[
1
]
[2]
5
3
4
5
2.47
Replace main PWB.
• Isn’t there any problem with the
door packing?
• Isn’t there any problem with the
installation condition?
(High temperature, Direct
sunlight, Installation space, etc.)
• Check the cold air outlet port and
inlet port of the refrigerating room
for blocking.
Remedy the problem.
NO
YES
NO
YES
For the resistance of the thermistor, refer to [8] 5. CONVERSION TABLE BETWEEN TEMPERATURE AND RESISTANCE VALUE
Replace R-thermistor.
Содержание SJ-RM320TB
Страница 12: ...SJ WS320T S 12 2 ELECTRIC ACCESSORIES LAYOUT 1 SJ WS320T RP320T ...
Страница 13: ...SJ WS320T S 13 2 SJ WP320T ...
Страница 14: ...SJ WS320T S 14 3 SJ RM320T WM322T ...
Страница 51: ...SJ WS320T S 51 12 COOLING UNIT 1 COOLING UNIT Mark Refrigerant flow ...