R-950A
25
5. Re-connect the wire leads (primary and high voltage)
and high voltage lead to the transformer and filament
leads of transformer to the magnetron and capacitor,
referring to the “Pictorial Diagram”.
6. Re-install the outer case and check that the oven is
operating properly.
NOTE: LIVE(ORANGE) WIRE MUST BE CONNECTED
TO THE CABINET-SIDE OF THE POWER
TRANSFORMER.
ASYMMETRIC RECTIFIER AND HIGH VOLTAGE RECTIFIER REMOVAL
MAGNETRON REMOVAL
1. CARRY OUT 3D CHECKS
2. Disconnect filament lead of transfomer and high voltage
wire lead from magnetron.
3. Take off three (3) screws secured the chassis support
to oven cavity and waveguide.
4. Remove the cooling fan assembly refer to “Cooling Fan
Removal”
5. Carefully remove four (4) mounting screws holding the
magnetron and magnetron air guide to waveguide.
When removing the screws hold the magnetron and
magnetron air guide to prevent it from falling.
6. Remove the magnetron from the waveguide with care
so the magnetron antenna should not hit by any metal
object around the antenna
CAUTION: WHEN REPLACING THE MAGNETRON, BE
SURE THE R.F. GASKET IS IN PLACE AND
THE MAGNETRON MOUNTING SCREWS
ARE TIGHTENED SECURELY.
1. CARRY OUT 3D CHECKS.
2. Disconnect wire leads from oven thermal cut-out,
convection motor, thermistor and convection heater.
Remove convection motor ass’y refer to “Convection
Motor Removal No.3 to No.5”.
3. Remove eleven (11) screws holding heater duct to the
oven cavity.
4. Release two (2) snap bands holding wire harness to
the thermal protection plate (left).
5. The heater unit is now free.
HEATING ELEMENT AND THERMISTOR
1. Remove two (2) screws holding convection heater to
heater duct.
2. Loosen two (2) screws holding holders to heater duct
and take convection heater out of heating element
holders.
3. Heating element is free.
4. Remove two (2) screws holding thermistor to heater
duct.
5. Thermistor is free.
HEATER UNIT ASSEMBLY REMOVAL (CONVECTION HEATER/ THERMISTOR)
1. CARRY OUT 3D CHECKS.
2. Pull the wire leads from the oven lamp socket by
pushing the terminal hole of the oven lamp socket
withthe flat type small screw driver.
3. Lift up the tab of oven lamp mounting plate holding the
oven lamp socket.
4. Slide the oven lamp socket left-ward.
5. Now, the oven lamp socket is free.
OVEN LAMP SOCKET REMOVAL
Oven lamp
socket
Terminal
Wire lead
Terminal hole
Flate type small
screw driver
HIGH VOLTAGE CAPACITOR REMOVAL
transformer.
5. Remove one (1) screw and washer holding the high
voltage rectifier from the capacitor holder.
6. Remove one (1) screw holding capacitor holder to rear
cabinet.
7. Remove the high voltage capacitor from the holder.
1. CARRY OUT 3D CHECKS.
2. Disconnect the high voltage wire leads and rectifier
assembly from the high voltage capacitor and magnetron.
3. Disconnect filament lead of transfomer from high voltage
capacitor.
4. Disconnect high voltage wire leads of capacitor from
CAUTION: WHEN REPLACING HIGH VOLTAGE REC-
TIFIER ASSEMBLY, ENSURE THAT THE
EARTHING SIDE TERMINAL MUST BE SE-
CURED FIRMLY WITH AN EARTHING
SCREW.
1. CARRY OUT 3D CHECKS.
2. Remove one (1) screw holding the high voltage rectifier
terminal to the capacitor holder.
3. Disconnect the high voltage rectifier assembly from
the capacitor.