R-950A
20
DESCRIPTION OF LSI
LSI(IZA850DR):
The I/O signals of the LSI(IZA850DR) are detailed in the following table.
Pin No.
Signal
I/O
Description
P03
ß(50Hz)
H
L
GND
VP
P02
P01
P00
P37
P36
P35
P55
During cooking
L
H
20 msec.
ON
OFF
During
cooking
L
GND
H.
(Convection)
ON
OFF
During
cooking
L
GND
H.
1
VCC
IN
Connected to GND.
2
VEE
IN
Anode (segment) of Fluorescent Display light-up voltage: -30V.
Vp voltage of power source circuit input.
3
AVSS
IN
Power source voltage: -5V.
VC voltage of power source circuit input.
4
VREF
IN
Reference voltage input terminal.
A reference voltage applied to the A/D converter in the LSI. Connected to
GND.(0V)
5-6
AN7-AN6
IN
Terminal not used.
7-9
AN5-AN3
IN
Heating constant compensation terminal.
10
AN2
IN
Input signal which communicates the door open/close information to LSI.
Door closed; "H" level signal(0V).
Door opened; "L" level signal(-5V).
11
AN1
IN
Input signal which communicates the damper open/close information to LSI.
Damper opened; "H" level signal(0V:GND).
Damper closed; "L" level signal(-5V).
12
AN0
IN
Temperature measurement input: OVEN THERMISTOR.
By inputting DC voltage corresponding to the temperature detected by the
thermistor, this input is converted into temperature by the A/D converter built into
the LSI.
13
P55
OUT
Digit selection signal.
The relationship between digit signal and digit are as follows;
Digit signal
Digit
P03 ........................... 1st.
P02 .......................... 2nd.
P01 .......................... 3rd.
P00 ........................... 4th.
P37 ........................... 5th.
P36 .......................... 6th.
P35 .......................... 7th.
P55 .......................... 8th.
Normally, one pulse is output in every ß
period, and input to the grid of the
Fluorescent Display.
14
P54
OUT
Oven lamp and turntable motor driving signal. (Square Waveform : 50Hz)
To turn on and off the shut-off
relay(RY1). The square waveform volt-
age is delivered to the relay(RY1) driv-
ing circuit.
15
P53
OUT
Convection motor driving signal.
To turn on and off shut-off relay(RY5). "L"
level during CONVECTION and during
back up for GRILL; "H" level otherwise.
16
P52
OUT
Cooling fan motor driving signal.
To turn on and off shut-off relay(RY6). "L"
level during both microwave and convec-
tion cooking; "H" level otherwise.
17
P51
OUT
Magnetron high-voltage circuit driving signal.
To turn on and off the cook relay(RY2). In HIGH operation, the signals holds "L"
level during microwave cooking and "H" level while not cooking. In other cooking
modes (MED HIGH, MED, MED LOW, LOW) the signal turns to "H" level and "L"
level in repetition according to the power level.