R-351NW
[6] POSITIVE LOCK CONNECTOR (NO-CASE TYPE) REMOVAL
[8] GRAPHIC SHEET AND MEMBRANE SWITCH REPLACEMENT
1. REMOVAL
1. CARRY OUT 3D CHECKS.
2. Remove the control panel assembly, referring to chapter of
CONTROL PANEL ASSEMBLY REMOVAL.
3. Remove the three (3) screws holding the control unit to the
control panel frame. And remove the control unit.
4. Remove the LCD holder and the rubber connector from the
control panel frame.
5. Tear away the graphic sheet from the control panel frame.
6. Tear away the membrane switch from the control panel
frame.
2. REINSTALLATION
1. Remove remaining adhesive on the control panel frame
surfaces with a soft cloth soaked in alcohol.
2. Tear the backing paper from the new membrane switch.
3. Insert the ribbon cable of the membrane switch into the slit
of the control panel frame.
4. Adjust the upper edge and right edge of the membrane
switch to the small depression on the surface of the control
panel frame.
5. Attach the membrane switch to the control panel frame by
rubbing with a soft cloth not to scratch.
6. Tear the backing paper from the new graphic sheet.
11 - 3
2. REINSTALLATION
1. Reinstall the magnetron to waveguide
fl
ange with the
four (4) screws.
2. Reinstall the air duct to the oven cavity top plate and
the magnetron with two (2) screws.
3. Insert the end of the chassis support into the hole of
the oven cavity front
fl
ange.
4. Hold the other end of the chassis support to the
magnetron with the one (1) screw.
5. Reconnect the wire leads to the magnetron. Refer to
“PICTORIAL DIAGRAM”.
6. Reinstall outer case and check that the oven is
operating properly.
CAUTION: WHEN REPLACING MAGNETRON, BE
SURE THE R.F. GASKET IS IN PLACE AND
MOUNTING SCREWS ARE TIGHTENED
SECURELY.
[7] CONTROL PANEL ASSEMBLY REMOVAL
1. Disconnect the power supply cord and remove outer case.
2. Open the door and block it open.
3. Discharge high voltage capacitor.
4. Disconnect the leads from the control unit.
1. Disconnect the power supply cord, and remove outer case.
2. Open the door and block it open.
3. Discharge high voltage capacitor.
4. Push the lever of positive lock
®
connector.
5. Pull down on the positive lock
®
connector.
CAUTION: WHEN CONNECTING THE POSITIVE LOCK
®
CONNECTORS TO THE TERMINALS, CONNECT
THE POSITIVE LOCK
®
SO THAT THE
LEVER
FACES
YOU
Terminal
Push
Pull down
1
2
Lever
Positive lock¨
connector
Figure C-1. Positive lock
®
connector
5. Remove the one (1) screw holding the control panel
assembly to the oven
fl
ange.
6. Slide the control panel assembly upward and remove it.
7. Now, individual components can be removed.
7. Adjust the upper edge and left edge of the graphic sheet
to the large depression on the surface of the control panel
frame.
8. Attach the graphic sheet to the control panel frame by
rubbing with a soft cloth not to scratch.
9. Make sure that the liquid crystal display and the LED sheet
are installed in position.
10. Tear the small backing paper from the ribbon cable of the
membrane switch.
11. Attach the ribbon cable to the control panel frame rear side.
12. Place the edge of the membrane switch’s ribbon cable on
the lower portion of the liquid crystal display.
13. Insert the rubber connector into the long slit of the LCD
holder.
14. Reinstall the control unit to the control panel frame with the
three (3) screws.
NOTE:
Do not contact the contact surface of the ribbon
cable (edge) and the rubber connector directly with
your
fi
ngers.
This is to avoid oxidized. If display digits are
missing or scrambled, remove control unit
and clean contact surface with alcohol.
Service_R-351NW.indd 26