2. Control Unit.
The following symptoms indicate a defective control unit.
1) In connection with pads.
a) When touching the pads, a certain group of pads do not produce a signal.
b) When touching the pads, no pads produce a signal.
2) In connection with indicators
a) At a certain digit, all or some segments do not light up.
b) At a certain digit, brightness is low.
c) Only one indicator does not light.
d) The corresponding segments of all digits do not light up; or they continue to light up.
e) Wrong
fi
gure appears.
f) A certain group of indicators do not light up.
g)
The
fi
gure of all digits
fl
icker.
3) Other possible problems caused by defective control unit.
a) Buzzer does not sound or continues to sound.
b) Clock does not operate properly.
c) Cooking is not possible.
3. If the Key unit or control unit is defective.
1) Disconnect the power supply cord, and then remove outer case.
2) Open the door and block it open.
3) Discharge high voltage capacitor.
4) Replace the control unit assembly.
5) Reconnect all leads removed from components during testing.
6) Re-install the outer case (cabinet).
7) Reconnect the power supply cord after the outer case is installed.
8) Run the oven and check all functions.
4. When testing is completed,
1) Disconnect the power supply cord, and then remove outer case.
2) Open the door and block it open.
3) Discharge high voltage capacitor.
4) Reconnect all leads removed from components during testing.
5) Re-install the outer case (cabinet).
6) Reconnect the power supply cord after the outer case is installed.
7) Run the oven and check all functions.
[12] K: KEY UNIT TEST
1. Disconnect the power supply cord, and then remove outer case.
2. Open the door and block it open.
3. Discharge high voltage capacitor.
4. Using an ohmmeter and referring to the key unit matrix indicated on the control unit circuit, check the circuit between the pins of the
key unit that correspond to the STOP/CLEAR pad. When the pad is pressed, the ohmmeter should indicate short circuit. When the
pad is released, the ohmmeter should indicate open circuit. If incorrect readings are obtained, the key unit is faulty and must be re-
placed. About the other pads, the above method may be used.
5. Reconnect all leads removed from components during testing.
6. Reinstall the outer case (cabinet).
7. Reconnect the power supply cord after the outer case is installed.
8. Run the oven and check all functions.
8 - 5
MINUTE
PLUS
STOP
CLEAR
POWER
LEVEL
WARM
COOK
POPCORN
SOFTEN
REHEAT
MELT
TIMER
CLOCK
7
8
9
3
6
0
5
2
1
4
START
DEFROST
G10
G9
G8
G7
G6
G5
G4
G3
G2
G1
Pin NO. G12
Pin NO. G1
Key unit ribbon cable
Key unit (Membrane Switch) front view
Service_R-351NW.indd 18
Service_R-351NW.indd 18
6/26/09 6:30:52 PM
6/26/09 6:30:52 PM