R343M - 12
1. CARRY OUT 3D CHECKS.
2. Make sure that a definite "click" can be heard when the
microwave oven door is unlatched. (Hold the door in a
closed position with one hand, then push the door open
button with the other, this causes the latch heads to rise,
it is then possible to hear a "click" as the door switches
operate.)
3. Visually check the door and cavity face plate for damage
(dents, cracks, signs of arcing etc.).
Carry out any remedial work that is necessary before
operating the oven.
Do not operate the oven if any of the following conditions
exist;
1. Door does not close firmly.
COMPONENT REPLACEMENT AND ADJUSTMENT
WARNING: Avoid possible exposure to microwave energy. Please follow the instructions below before
operating the oven.
2. Door hinge, support or latch hook is damaged.
3. The door gasket or seal is damaged.
4. The door is bent or warped.
5. There are defective parts in the door interlock system.
6. There are defective parts in the microwave generating
and transmission assembly.
7. There is visible damage to the oven.
Do not operate the oven:
1. Without the RF gasket (Magnetron).
2. If the wave guide or oven cavity are not intact.
3. If the door is not closed.
4. If the outer case (cabinet) is not fitted.
Please refer to ‘OVEN PARTS, CABINET PARTS, DOOR PARTS’, when carrying out any of the following removal
procedures:
MONITORED LATCH SWITCH, MONITORED SWITCH AND STOP SWITCH REMOVAL
REMOVAL
1. CARRY OUT 3D CHECKS.
2. Push the open button and open the door slightly.
3. Insert a putty knife (thickness of about 0.5mm) into the
gap between the choke cover and door frame as shown
in Figure C-5 to free engaging parts.
4. Release choke cover from door panel.
5. Now choke cover is free.
CHOKE COVER
PUTTY KNIFE
DOOR FRAME
MONITOR SWITCH
STOP SWITCH
MONITORED
LATCH SWITCH
TAB
TAB
TAB
Figure C-3. Switches
6. Release two (2) pins of door panel from two (2) holes of
upper and lower oven hinges by lifting up.
7. Now, door sub assembly is free from oven cavity.
8. Remove the four (4) screws holding the door panel to the
door frame.
9. Release door panel from eight (8) tabs of door frame by
sliding door panel downward.
10. Now, door panel is free.
11. Slide latch head upward and remove it from door frame by
releasing latch spring from door frame and latch head.
12. Now, latch head and latch spring are free.
13. Remove the two (2) screws holding the glass stopper to the
door frame.
14. Remove the glass stopper from the door frame.
15. Slide the front door glass leftwards and then slide upwards
to release the tabs holding it.
16. Now, the front door glass is free
1. CARRY OUT 3D CHECKS.
2. Remove the control panel assembly referring to "CONTROL
PANEL ASSEMBLY REMOVAL".
3. Disconnect the all leads from the switches.
4. Remove the two (2) screws holding the latch hook to the oven
cavity.
5. Remove the latch hook.
6. Push the retaining tab slightly and remove the switch.
Figure C-5. Door Disassembly
DOOR REPLACEMENT