23
E
You can return the settings to their factory-preset values and
restrict operations.
1. Hold down the [MENU/ENTER] button and [INPUT/
RETURN] button at the same time until “F” appears in
the screen, and then press the [MENU/ENTER] button
and [VOL-/ ] button at the same time while “F”
appears.
▲
▲
▲
▲
▲
▲
▲
▲
▲
▲
▲
▲
▲
OFF
UNLOCKED
ON 1
ON
OFF
OFF
FUNCTION
ALL RESET
ADJUSTMENT LOCK
RS-232C
OSD DISPLAY
LED
TEMPERATURE ALERT
STATUS ALERT
END…[RETURN]
OK…[ENTER]
2. Select and set the items.
ALL RESET
Resets the settings to the factory default settings.
Select ALL RESET, and then press [MENU/ENTER]
button.
After initialization, turn the main power switch off and
then back on.
ALL RESET ......Resets all the settings to the factory
default settings.
CANCEL ...........Go back without resetting.
ADJUSTMENT LOCK
You can disable operations on the monitor buttons.
OFF ...Enables operation.
ON 1 ..Disables all operations other than turning power
on/off and FUNCTION.
ON 2 ..Only the FUNCTION operation is enabled.
Disables all operations other than FUNCTION (not
even power on/off).
RS-232C
Specifies whether to allow control via RS-232C. (See
page 24.)
OSD DISPLAY
Shows/hides the menu, modes and messages.
The FUNCTION screen cannot be hidden.
ON 1 .............. Shows all menus, modes and messages.
ON 2 .............. Hides messages automatically displayed
by the display. Shows messages during
operation.
OFF ............... Hides all menus, modes and messages.
LED
Specifies whether to light the power LED.
Initialization (Reset)/Functional Restriction Setting (FUNCTION)
TEMPERATURE ALERT
Selects the notification method for an abnormal
temperature.
OFF .............. Do not notify about an abnormal
temperature.
OSD & LED .. When an abnormal temperature is
detected, the power LED flashes in red
and green alternately and the screen
displays a message: TEMPERATURE.
LED............... When an abnormal temperature is
detected, the power LED flashes in red
and green alternately.
STATUS ALERT
Selects the notification method for a hardware error.
OFF .............. Do not notify about the error.
OSD & LED .. When a hardware error is detected, the
power LED flashes in red and the screen
displays a message: STATUS [xxxx].
LED............... When a hardware error is detected, the
power LED flashes in red.
3. Press [INPUT/RETURN] button to return to the normal
screen.
TIPS
• When both abnormal temperature and hardware error are
detected, the hardware error notification overrides.
• If TEMPERATURE ALERT or STATUS ALERT is set to
OSD & LED, alert messages will appear even if the OSD
DISPLAY is set to ON 2 or OFF.
• If TEMPERATURE ALERT or STATUS ALERT is set to LED
or OSD & LED, the LED lights even if the LED function is
set to OFF.
Содержание PN-K321