ENGLISH
E
29
RS-232C command table
How to read the command table
Command:
Command field (See page 25.)
Direction:
W When the “Parameter” is set in the parameter field (see page 25), the command functions as described
under “Control/Response Contents”.
R The returned value indicated under “Reply” can be obtained by setting “????”, “
?” or “???+”
(repeater control) in the parameter field (see page 25).
Parameter:
Parameter field (See page 25.)
Reply:
Response (Returned value)
*:
“Yes” indicates commands which can be used in power standby mode.
Power control/Input mode selection
Function
Command Direction
Parameter
Reply
Control/Response contents
*
POWER CONTROL
POWR
W
0
Switches to standby mode.
Yes
1
Returns from standby mode.
R
0 Standby mode
1 Normal mode
2 Input signal waiting mode
INPUT MODE SELECTION
INPS
W
0
Toggle change for input mode
Terminals not selected in DVI SELECT/BNC SELECT cannot be
selected.
Yes
1
PC1 DIGITAL
“ERR” when AV (DIGITAL) is selected for DVI SELECT.
2
PC2 ANALOG
3
AV2 COMPONENT
“ERR” when PC (ANALOG) is selected for BNC SELECT.
4
AV3 VIDEO
6
PC3 ANALOG
“ERR” when AV (COMPONENT) is selected for BNC SELECT.
7
AV1 DIGITAL
“ERR” when PC (DIGITAL) is selected for DVI SELECT.
R
1 PC1 DIGITAL
2 PC2 ANALOG
3 AV2 COMPONENT
4 AV3 VIDEO
6 PC3 ANALOG
7 AV1 DIGITAL
SCREEN menu (PC2/PC3)
Function
Command Direction
Parameter
Reply
Control/Response contents
*
AUTO
ASNC
W
1
No
CLOCK
CLCK
WR
0-255
0-255
No
PHASE
PHSE
WR
0-63
0-63
POSITIONING
POSITION OF
THE LONGEST
DIRECTION
HPOS
WR
0-500
0-500 A maximum value depends on a resolution.
POSITION OF
THE SHORTEST
DIRECTION
VPOS
WR
0-100
0-100
RESET
ARST
W
1
No
Controlling the Monitor with a PC