background image

SIM02E-005B 

 

 

Annex 

(normative) 

 

 

 

 

【Test load】

【Design load】

Table.A1-1 Test load using clamps on long frames (see Fig. A1)

Table.A1 Design load using clamps on long frames (see Fig. A1)

clamp center position

clamp center position

(e: mm)

downward force

upward force

(e: mm)

downward force

upward force

240 < e <335

5,400Pa

3,600Pa

240 < e <335

3,600Pa

2,400Pa

    0 < e <441

2,400Pa

2,400Pa

    0 < e <441

1,600Pa

1,600Pa

Table.A2-1 Test load using clamps on short frames (see Fig. A2)

Table.A2 Design load using clamps on short frames (see Fig. A2)

clamp center position

clamp center position

(e: mm)

downward force

upward force

(e: mm)

downward force

upward force

   0< e <262

1,800Pa*

1,800Pa*

   0< e <262

1,200Pa

1,200Pa

Table.A3-1 Test load using Bolt Holes (see Fig. A3,A3-1)

Table.A3 Design load using Bolt Holes (see Fig. A3,A3-1)

bolts & nuts

bolts & nuts

(position of using holes)

downward force

upward force

(position of using holes)

downward force

upward force

4points at "a" holes 

5,400Pa

3,600Pa

4points at "a" holes 

3,600Pa

2,400Pa

Table.B-1 Test load using clamps on long & short frames (see Fig. B)

Table.B Design load using clamps on long & short frames (see Fig. B)

clamp center position

clamp center position

(L, S: mm)

downward force

upward force

(L, S: mm)

downward force

upward force

   0< L <441 , 0< S <262

1,800Pa*

1,800Pa*

   0< L <441 , 0< S <262

1,200Pa

1,200Pa

The Test load has been calculated with a safety factor of 1.5 from the design load.

* Test procedure according to IEC 61215-2:2016. The test results are based on internal evaluation. 

 test load according to IEC61215

design load according to IEC61215

 test load according to IEC61215

design load according to IEC61215

design load according

design load according

 test load according to IEC61215

design load according to IEC61215

1. Spring washer                                        2.  Washer 
    Material: Stainless steel    

Material: Stainless steel 

    Diameter: M8 8.2/15.4mm                      

Diameter: M8 8.5/15.5mm 

    Thickness: 2 mm (reference value)         

Thickness: 1.6 mm (reference value) 

3. Bolt                                                         4.  Nut 
    Material: Stainless steel                              Material: Stainless steel                             
    Size: M8                                                      Size: M8 
    Diameter:  M8 x 20mm 

 

Fig. A3-1 : The components for BOLT & NUT 

Содержание NU-JC365B

Страница 1: ... GENERAL INSTRUCTIONS 1 INTRODUCTION This INSTALLATION MANUAL contains essential information for the electrical and mechanical installation that you must know before installing SHARP PV modules This also contains safety information you need to be familiar with All the information described in this manual are the intellectual property of SHARP and based on the technologies and experiences that have...

Страница 2: ... SAFETY 1 Do not cause an excessive load on the surface of PV module or twist the frame The glass surface or cells in the PV module can easily break 2 Do not stand or step on the PV module The surface glass of PV module is slippery Besides the weight may cause PV module damage 3 Do not hit or put excessive load on the glass or back sheet The PV cell is very thin and can be easily broken 4 Do not s...

Страница 3: ...d connection using a bolt nut and washer retaining a ground lug is shown in Figure 3 In a connection of this type the hardware such as a toothed locked washer star washer must score the frame surface to make electrical contact with the frame The ground wire must be considered within the local requirement of local and regulation at the site of installation 8 MOUNTING Please make sure that all the i...

Страница 4: ... on the module itself will remain valid according the applicable terms 3 WARNING Keep all PV MODULES and electrical CONNECTORS clean dry before installation 4 Disposal Dispose PV modules properly For Information about the proper disposal contact your local recycling site ELECTRICAL OUTPUT AND THERMAL CHARACTERISTICS Rated electrical characteristics are within 10 percent of the indicated values of ...

Страница 5: ...t a holes 5 400Pa 3 600Pa 4points at a holes 3 600Pa 2 400Pa Table B 1 Test load using clamps on long short frames see Fig B Table B Design load using clamps on long short frames see Fig B clamp center position clamp center position L S mm downward force upward force L S mm downward force upward force 0 L 441 0 S 262 1 800Pa 1 800Pa 0 L 441 0 S 262 1 200Pa 1 200Pa The Test load has been calculated...