4. SITE SELECTION

 

In most applications, the PV modules should be installed in a 
location where there is no shading throughout the year. In the 
Northern Hemisphere, the PV modules should typically face  
south, and in the Southern Hemisphere, the PV modules should 
typically face north. 
Please  make  sure  that  there  are  no  obstructions  in  the 
surroundings of the site of installation. TAKE PROPER STEPS 
in  order  to  maintain  reliability  and  safety,  in  case  the  PV 
modules  are  used  in  areas  such  as:  Heavy  snow  areas  / 
Extremely cold areas / Strong wind areas / Installations over, or 
near, water / Areas where installations are prone to salt water 
damage/corrosive  gas  environment/  Small  islands  or  desert 
areas. 
The results of the ammonia test and the salt-mist-corrosion test 
on the PV modules, carried out under such strict test conditions, 
should be disclosed for reference purposes only. The decision 
on  whether  the  PV  modules  are  suitable  and  compatible  for 
each installation field 

will depend on the user’s judgement and 

responsibility. 

 

5. TILT ANGLE 

The tilt angle is the measurement between the PV module and 
a  horizontal  ground  surface.  The  PV  module  generates  the 
maximum output power when it faces the sun directly.  
5 degrees or more is recommended for the tilt angle of the PV 
module for the maintenance (See 9. Maintenance). 
For  the  standalone  systems  with  a  battery  where  the  PV 
modules are attached to a permanent structure, the tilt angle of 
the  PV  modules  should  be  determined  to  optimize  the 
performance when the sunlight is the scarcest. In general, if the 
electric power generation is adequate when the sunlight is the 
scarcest, then the angle chosen should be adequate during the 
rest of the year. For grid-connected installations where the PV 
modules  are  attached  to  a  permanent  structure,  it  is 
recommended  to  tilt  the  PV  module  at  the  angle  equal  to  the 
latitude of the installation site so that the power generation from  
the PV module will be optimum throughout the year. 

 

6. WIRING 

To  ensure  proper  system  operation  and  to  maintain  your 
guaranty, observe the correct cable connection polarity (Figures 
1 & 2) when connecting the PV modules to a battery or to other 
PV modules. If not connected correctly, the bypass diodes could 
be destroyed. 
PV modules can be wired in series to increase voltage. Connect 
wires  from  the  positive  terminal  of  one  PV  module  to  the 
negative  terminal  of  the  next  PV  module.  Figure  1  shows  PV 
modules connected in series. 
Connect  PV  modules  in  parallel  to  increase  current.  Connect 
wires from the positive terminal of one PV module to the positive 
terminal on the  next  PV module. Figure 2 shows  PV modules 
connected in parallel. 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

7. GROUNDING 

The frame grounding must consider the local requirement and 
regulation at the  installation site. When grounding is required, 
please refer to below example connection (Figure  3).   Please 
be careful in arranging the system ground so that the removal 
of one PV module from the circuit will not interrupt the grounding 
of any other PV modules. 

The  PV  modules  should  be  grounded  to  the  same  electrical 
point as described below. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

You can use a hole with the appropriate symbol for equipotential 
bonding  on  the  side  frame  for  either  a  bolt,  nut  and  washer 
grounding the PV module to the frame, a ground lug fastened 
by bolt or screw, or appropriate screw (hardware not provided). 
An example of acceptable ground connection using a bolt, nut 
and  washer  retaining  a  ground  lug  is  shown  in  Figure  3.  In  a 
connection of this type, the hardware (such as a toothed locked 
washer  /  star  washer)  must  score  the  frame  surface  to  make 
electrical  contact  with  the  frame.  The  ground  wire  must  be 
considered within the local requirement of local and regulation 
at the site of installation. 

 
8. MOUNTING 

Please  make  sure  that  all  the  information  described  in  the 
INSTALLATION  MANUAL  is  still  valid  and  proper  for  your 
installation. The mounting method has been verified by SHARP 
and NOT CERTIFIED by a third party organization. 
The approved way to mount SHARP PV modules to a support 
structure is described in this INSTALLATION MANUAL. 
Although SHARP does not specify or warrant frame clamps or 
clips, using frame clamps (not provided) or clips (not provided) 
is  possible  when  they  are  designed  for  PV  modules  and  with 
minimum  dimensions  on  the  sides  of  the  PV  module  in 
accordance with the instructions and drawings provided. If using 
frame clamps or clips, the PV modules should be fixed rigidly 
and there shall be no damage to the PV modules by deforming 
mounting structure against design load.  
The  SHARP  PV  module  guaranty  may  be  void  if  customer-
selected  frame  clamps  are  improper  or  inadequate  for  PV 
module properties (including strength or material) or installation. 
Note  that  if  metal  clamps  are  used,  there  must  be  a  path  to 
ground from the clamps, (for instance, using star washers in the 
clamp  hardware  set).Please  review  the  descriptions  and 
drawings carefully; not mounting the PV modules according to 
one of these methods may void your guaranty. The PV module 
has  passed  the  test  sequence  which  contains  3  cycles  each 
performed at 5,400 Pa positive and 2,400 Pa negative loading 
in accordance with IEC61215-2. The system designer shall be 
responsible to ensure protective structures so that the module 
can bear to the loads that are different from the test condition 
defined in the IEC standard.  
Support structures that PV modules are mounted on should be 
rigid.  SHARP  PV  modules  are  designed  to  ensure  optimal 
electrical  performance  under  the  condition  that  they  are 
mounted  on  rigid  support  structures.  Deformation  of  support 
structure may damage PV module with its electric performance. 
When  mounting  the  PV  module  on  structure,  ensure  that  no 
corner  has  a  displacement  of  more  than  2mm  per  every 
1000mm of the diagonal.

 

The mounting structure shall enable 

the PV module to deflect freely under wind and/or snow load not 
to make direct impact to the center of the PV module.(i.e. min.     
10 cm from the roof surface to the bottom face of  PV module 
frame). The installer shall be responsible for the selection and 
construction of support structure. 

 

9. MAINTENANCE 

The PV modules are designed for long life and require very little 
maintenance. If the angle of the PV module is 5 degrees or more, 
normal rainfall is sufficient to keep the PV module glass surface 
clean under most weather conditions. If dirt build-up becomes 
excessive, use only a soft, damp cloth and water to clean the 
glass. If cleaning the back of the  PV module is required, take 
utmost care not to damage the back side materials. In order to 
ensure  the  operation  of  the  system,  check  the  connection  of 
wiring and the state of the jacket of wires occasionally. 
The PV modules is equipped with anti-reflective coating glass, 
do  not  touch  the  glass  since  finger  prints  or  stains  will  easily 
mark.  If  dirt  build-up  becomes  excessive,  clean  the  glass 
surface with water only. 
 

SIM201-004 

 Bypass Diode 

(Built-in Junction Box) 

 Bypass Diode 

(Built-in Junction Box) 

Содержание NU-JC365B

Страница 1: ... GENERAL INSTRUCTIONS 1 INTRODUCTION This INSTALLATION MANUAL contains essential information for the electrical and mechanical installation that you must know before installing SHARP PV modules This also contains safety information you need to be familiar with All the information described in this manual are the intellectual property of SHARP and based on the technologies and experiences that have...

Страница 2: ... SAFETY 1 Do not cause an excessive load on the surface of PV module or twist the frame The glass surface or cells in the PV module can easily break 2 Do not stand or step on the PV module The surface glass of PV module is slippery Besides the weight may cause PV module damage 3 Do not hit or put excessive load on the glass or back sheet The PV cell is very thin and can be easily broken 4 Do not s...

Страница 3: ...d connection using a bolt nut and washer retaining a ground lug is shown in Figure 3 In a connection of this type the hardware such as a toothed locked washer star washer must score the frame surface to make electrical contact with the frame The ground wire must be considered within the local requirement of local and regulation at the site of installation 8 MOUNTING Please make sure that all the i...

Страница 4: ... on the module itself will remain valid according the applicable terms 3 WARNING Keep all PV MODULES and electrical CONNECTORS clean dry before installation 4 Disposal Dispose PV modules properly For Information about the proper disposal contact your local recycling site ELECTRICAL OUTPUT AND THERMAL CHARACTERISTICS Rated electrical characteristics are within 10 percent of the indicated values of ...

Страница 5: ...t a holes 5 400Pa 3 600Pa 4points at a holes 3 600Pa 2 400Pa Table B 1 Test load using clamps on long short frames see Fig B Table B Design load using clamps on long short frames see Fig B clamp center position clamp center position L S mm downward force upward force L S mm downward force upward force 0 L 441 0 S 262 1 800Pa 1 800Pa 0 L 441 0 S 262 1 200Pa 1 200Pa The Test load has been calculated...

Отзывы: