MX-FNX9 DISASSEMBLY AND ASSEMBLY 6 – 7
8)
Remove the alignment plate. Remove the screws and the
pawl, and remove the process tray.
9)
Slide the unit and remove the alignment motors F and R.
(2) Empty sensor, alignment plate HP sensors F and R
1)
Remove the inner finisher from the main unit. Refer to A-(1).
2)
Remove the inner cover. Refer to A-(2).
3)
Remove the tray unit. Refer to B-(10).
4)
Remove the process tray unit. Refer to C-(1).
5)
Remove the bracket and the empty sensor. Remove the align-
ment plate HP sensors F and R.
D. Staple section
(1) Staple cartridge
1)
Open the front cover, and slide the inner finisher. Refer to B-
(1).
2)
Release the lock, and remove the staple cartridge.
(2) Staple unit
1)
Remove the inner finisher from the main unit. Refer to A-(1).
2)
Remove the inner cover. Refer to A-(2).
3)
Remove the latch cover. Remove the parts and the shaft.
4)
Remove the screw from the bottom. Remove the staple unit,
and disconnect the connector.
1
2
1
2
4
3
5
1
2