WRITE:
Writing of patch data
VERIFY:
Verifying patch data (The display is made in an in-
stant.)
9. End of patch writing
When patch writing is completed, the bar display is cleared. At the
same time, the check sum is displayed on the lower right side.
Note: The following operations of patch erase, write, and verify
should be performed immediately after entering the diag mode
by "ON" + "D" + "Reset."
Do not perform the operations after checking the other items.
43
ERASE
1M
FLASH
45
VERIFY
1M
FLASH
47
UPDATE
1M
FLASH
5-3. Copying patch data to products from the
ZR-3500X master unit
<Tools>
1
ZR-3500X master unit
2
Data transfer cable CE-315L
(Procedure)
Connect the master set and the slave set with the cable.
(Slave side)
1. Start the DIAG menu. ("ON" + "D" + "RESET")
2. Touch the menu key three times.
3. Touch "43. ERASE 1M FLASH."
4. Touch "47. UPDATE 1M FLASH."
(Master side)
1. Start the DIAG. menu. ("ON" + "D" + "RESET")
2. Touch the menu key three times.
3. Touch "49. PATCH MASTER."
* NOTE: It is required that the master unit and the slave unit
should be of the same ROM version.