• UTOC was read but total TNO and the number of characters of
NAME was 0?
• Focusing error was caused by shock during REC-PLAY.
• Although UTOC can be read but UTOC cannot be rewritten.
• Data of EEPROOM is not correct.
Error display
Errors
Corrective action
BLANK MD
DEFECT
TOC W ERROR
MD ERROR
• Perform recording to check that the disc
is recordable disc.
• Check that the disc is free from flaw,
dust, fingerprint and black spot. Check for
disc disalignment and run-out.
• Check that the record head contact is
normal. Check that there is no broken wire
between PWB and the recording head.
• Perform adjustment
• Once reset, and redo. If error occurs
persistently, replace EEPROM.
EXPLANATION OF MECHANISM ERROR
Error display
Errors
M E C H A _ E R R 1 _ *
Ejection failure
M E C H A _ E R R 2 _ *
Head-up failure
M E C H A _ E R R 3 _ *
Head-down failure
HINF (IC1401 97 PIN)
* = E Ejection completion position
< 1.3 V
* = M Horizontal midway position
> 3.06 V
* = L Load completed position
1.853~2.48 V
* = D Head-down position
1.3~1.853 V