ENGLISH
E-11
After replacing the unit, ensure that turn on the Operation Switch is turned on
to see that the Operation Light (blue) is lighting.
HOW TO REPLACE THE PLASMACLUSTER ION GENERATING UNIT
*1 It is the value measured at point in wind blowing direction from air outlet when the product is operated with
a stand opened.
*2 The dimension when the clamp is installed horizontally (not including the clamp screw).
*3 The height is the dimension when the arm is extended straight.
Model
IG-DL1Y
Power Supply
220-240V, 50/60 Hz
Operaqtion Mode
Plasmacluster Ion Operation
Ion Density (ions/cm
3
)
*1
70 cm : Approx. 100,000 1 m : Approx. 25,000
Total luminous
fl
ux (lm)
10
Air
fl
ow Volume (m
3
/min)
0.14
Power Consumption (W)
1.2 (Using the spotlight : 1.8)
Operating noise level (dBA)
25
Dimensions
*3
(mm)
When installing the stand
190(W) x 565(H) x 200(D)
When installing the clamp
*2
90(W) x 605(H) x 110(D)
Weight (kg)
When installing the stand
Approx. 1.2
When installing the clamp
Approx. 0.7
Cord length (m)
Approx. 1.8
SPECIFICATIONS
1
2
3
Remove the Filter Cap
Remove the Unit
Reinstall a new Unit and Filter Cap
①
①
①
②
②
②
Hold the cap hook.
Pull the unit
fi
xing tabs, and
Insert the unit with the electrode section facing inward.
Ensure that the cap hook and the tabs are in place.
Reinstall a new Unit
Reinstall the
Filter Cap
Remove the
fi
lter cap.
Remove the unit.
Cap hook
Filter cap
Unit
Unit
fi
xing tab
Tab
Electrode section
Unit
IG-DL1Y̲en.indd Sec1:11
IG-DL1Y̲en.indd Sec1:11
2011/10/25 16:43:11
2011/10/25 16:43:11