FO-DC600U
2 – 34
SW76 No. 7 MTF correction in half-tone mode
In the half tone mode, image area is separated from character area and
processed separately to eliminate unclear character transmission. This
switch is used to change the criteria of judgement of separation. When
"Strong" (= 1) is selected, more area is judged as character area, pro-
viding clearer characters.
On the contrary, however, edges of image area may be emphasized.
It is advisable to restrict the use of this function only when clear charac-
ters must be transmitted, and to use the function of "Weak" (= 0) for
general cases.
SW76 No. 8 MTF intensity in half-tone mode
This allows selection of MTF correction (dimness correction) in the half
tone mode. When "NO" (= 1) is selected, the whole image becomes soft
and mild, On the contrary, however, mildness of characters will be re-
duced. Normally set to "NO" (= 1).
SW77 No. 1 Cassette define LTR / A4:Tray
A4 cassette can be used .
Set "0" or "1" for all of three bits.
Do not change the setting during printing.
SW77 No. 2 Cassette define LTR / A4:Upper
A4 cassette can be used .
Set "0" or "1" for all of three bits.
Do not change the setting during printing.
SW77 No. 3 Cassette define LTR / A4:Upper
A4 cassette can be used .
Set "0" or "1" for all of three bits.
Do not change the setting during printing.
SW77 No. 4 ~ No. 8 Reserved
Set to "1".
SW78 No. 1 Reserved
Set to "1".
SW78 No. 2 ~ No. 8 Reserved
Set to "0".
SW79 No. 1 Secure billing code
When the tel. billing code function is ON, the operation of secure billing
code is enabled .
SW79 No. 2 Pause with SHIFT key
The SHIFT key pause time is set.
SW79 No. 3 Reserved
Set to "0".
SW79 No. 4 ~ No. 8 Z key pause time (250ms unit)
The Z key pause time is set.
SW80 No. 1 Separate feature
The separate mode ON/OFF is set.
SW80 No. 2 ~ No. 4 Reserved
Set to "0".
SW80 No. 5 Addition of header (Sender information)
ON/OFF of addition of header (sender information) to various list is set.
SW80 No. 6 DTMF sending by the panel test
When ten keys are pressed in the Panel Test Mode of the diagnosis, the
corresponding DTMF signals are output.
SW80 No. 7 Power save mode
To switch power save mode system either to real time or to timer.
SW80 No. 8 Ring control for line-2
The ringer ringing ON/OFF is set when incoming call is received through
the line-2.
SW81 No. 1 Reserved
Set to "1".
SW81 No. 2 Reserved
Set to "0".
SW81 No. 3 ~ No. 8 Reserved
Set to "1".
SW82 No. 1 Reserved
Set to "0".
SW82 No. 2 Reserved
Set to "1".
SW82 No. 3 Reserved
Set to "0".
SW82 No. 4 Reserved
Set to "1".
SW82 No. 5 ~ No. 8 Reserved
Set to "0".
SW83 No. 1 ~ No. 5 Reserved
Set to "0".
SW83 No. 6 Reserved
Set to "1".
SW83 No. 7 Reserved
Set to "0".
SW83 No. 8 Reserved
Set to "1".
SW84 No. 1 ~ No. 4 Reserved
Set to "0".
SW84 No. 5 ~ No. 8 Reserved
Set to "1".
SW85 No. 1 ~ No. 8 Reserved
Set to "0".
SW86 No. 1 ~ No. 8 Reserved
Set to "0".
SW87 No. 1 File name (Unique identifier)
The file names of the E-MAIL notice and files from the FTP server will be
automatically created from the following elements. By setting the SWs
below, file names with these elements are generated. : A unique number
generated from the machine serial number and the date and time data.
SW87 No. 2 File name (Session page counter)
The file names of the E-MAIL notice and files from the FTP server will be
automatically created from the following elements. By setting the SWs
below, file names with these elements are generated. : Counter
SW87 No. 3 File name (Date & Time)
The file names of the E-MAIL notice and files from the FTP server will be
automatically created from the following elements. By setting the SWs
below, file names with these elements are generated. : Date and time
data
SW87 No. 4 File name (Profile name)
The file names of the E-MAIL notice and files from the FTP server will be
automatically created from the following elements. By setting the SWs
below, file names with these elements are generated. : Sender’s name
SW87 No. 5 ~ No. 8 Reserved
Set to "0".
SW88 No. 1 ~ No. 4 Default file format
SW setting the default of the compression format and the file type re-
quired for generating the image data from network scanned data.
SW88 No. 5, No. 6 The default resolution for Network Scanning
SW setting the default resolution on network scanning.
SW88 No. 7, No. 8 Reserved
Set to "0".
SW89 No. 1 ~ No. 7 Reserved
Set to "0".
SW89 No. 8 Reserved
Set to "1".
SW90 No. 1, No. 2 Reserved
Set to "0".
SW90 No. 3 Reserved
Set to "1".
SW90 No. 4, No. 5 Reserved
Set to "0".
SW90 No. 6 Reserved
Set to "1".
SW90 No. 7 Reserved
Set to "0".
Содержание FO-DC600
Страница 98: ...FO DC600U Control PWB parts layout Top side 6 16 F1 F2 F5 ...
Страница 99: ...FO DC600U Control PWB parts layout Bottom side 6 17 F100 F101 F102 ...
Страница 101: ...FO DC600U LIU PWB parts layout Top side 6 19 ...
Страница 102: ...FO DC600U LIU PWB parts layout Bottom side 6 20 ...
Страница 105: ...FO DC600U Printer PWB parts layout Top side 6 23 ...
Страница 106: ...FO DC600U Printer PWB parts layout Bottom side 6 24 ...
Страница 108: ...FO DC600U Power Supply PWB parts layout 6 26 The Power supply PWB of this model employs lead free solder ...