AR-M280U SIMULATIONS 9-1
[9] SIMULATION
The following simulations have been changed.
<List of display value>
<List of set values>
<List of set values>
Main code 8
8-6
Purpose
Adjustment
Function (Content)
Used to check and adjust the transfer charger
current and its control circuit.
Section
Process
(OPC drum, developing, transfer, cleaning)
Item
Operation/Procedure Enter the output value to be adjusted with
10 digit key pad. The current set value is
highlighted at the right of each item.
After entering the value with 10 digit key pad,
press START key.
The output is made for 30sec at the set value.
Then the output is stopped.
Default
Set range
1 Cassette/manual paper feed
45PPM
267
0 ~ 620
28/35PPM 220
2 Paper feed from ADU
45PPM
310
28/35PPM 267
1
SIMULATION 8-6
THV+SETTING. INPUT VALUE, AND PRESS START.
1. FRONT(0-620)
140
SIMULATION 8-6
THV+SETTING. EXECUTING...
1. FRONT
140
SIMULATION 8-6
THV+SETTING. SELECT 1-2, AND PRESS START.
1. FRONT
140
2. BACK
140
Or after 30sec output
Press [START] key.
Press [CUSTOM SETTING] key.
Press [START] key.
Press [CUSTOM SETTING] key.
8-17
Purpose
Operation test, check
Function (Content)
Used to set and check the transfer roller output.
Section
Process
(OPC drum, developing, transfer, cleaning)
Item
Operation
Operation/Procedure Enter the output value to be adjusted with
10 digit key pad. The current set value is
highlighted at the right of each item.
After entering the value with 10 digit key pad,
press START key.
The output is made for 30sec at the set value.
Then the output is stopped.
Default
Set range
1
SHV front surface
160(45PPM)
120(28/35PPM)
0 ~ 375
2
SHV back surface
3
THV-output
780
0 ~1250
Main code 21
21-1
Purpose
Setup
Function (Content)
Used to set the maintenance cycle.
Section
Item
Spec
Operation/Procedure Used to set the maintenance cycle in an SRU
machine.
0
Maintenance display at the cycle of each control spec.
1
Maintenance display at 5K
2
Maintenance display at 10K
3
Maintenance display at 25K
4
Maintenance display at 50K
5
Maintenance display at 80K
6
No maintenance display
7
Maintenance display at 100K
8
Maintenance display at 20K
9
Maintenance display at 40K
1
SIMULATION 8-17
TRANSFER ROLLER SETTING. INPUT VALUE, AND PRESS START.
1. FRONT (0-375)
500
SIMULATION 8-17
TRANSFER ROLLER SETTING. EXECUTING...
1. FRONT (0-375)
500
SIMULATION 8-17
TRANSFER ROLLER SETTING. SELECT 1-3, AND PRESS START.
1. SHV FRONT
500
2. SHV BACK
500
3. THV-
500
Or after 30sec output
Press [START] key.
Press [CUSTOM SETTING] key.
Press [START] key.
Press [CUSTOM SETTING] key.
SIMULATION 21-1
MAINTENANCE CYCLE SETUP. SELECT 0-6, AND PRESS START.
0. DEFAULT 1. 5K 2. 10K 3. 25K
4. 50K 5. 80K 6.FREE 7. 100K 8. 20K 9. 40K
1
!"#$%&