LC-60/70EQ10U,SQ10U/15U/17U,TQ15U,UQ17U
5 – 27
5. On Setting Items
* “EZ-SETUP” discussed below indicates “EZ-SETUP after the first power-on”.
1) POWER ON FIXED
2) MAXIMUM VOLUME
3) VOLUME FIXED
4) VOLUME FIXED LEVEL
5) RC BUTTON
Selection
Selection between “Variable” and “Fixed” (loop provided)
Default
– (Variable)
Explanation
In “Fixed” setting, the power-off by the power key of the unit is invalidated and the image is kept being received. The power can
be turned off by stopping the power supply from AC.
Limit in Setting
Refer to the “Power-On Fixed” sheet.
Exception
None
Remarks
•
In “Variable” setting, the power operation is in wait for 1 sec. and then turned off when the main power switch is off.
Selection
Adjustment from 0 to 60 (no loop)
Default
60
Explanation
Sound volume can not be adjusted higher than the preset value.
Limit in Setting
•
When the sound volume is set lower than 59, only figures are displayed and the sound volume bar is not displayed.
•
The maximum sound volume for ON-timer (Wake up timer) is limited also to the preset value.
Exception
Remarks
•
When the sound volume is set higher than the MAX setting by the adjusting process, the sound volume control operation is
prohibited for turn-up and the sound volume should be turned down to MAX in this state.
Selection
Selection between “Variable”, “Fixed”, “ACON (AC CTRL)” and “AC/RCON (AC/RC CTRL)” (loop provided)
Default
Variable
Explanation
•
FIXED: Fixed at the level adjusted for a fixed volume.
•
AC CTRL: Start-up at the level specified for a fixed volume at ACON.
•
AC/RC CTRL: Start-up at the level specified for a fixed volume at start.
Limit in Setting
•
The sound volume for the ON-timer (Wake up timer) is fixed also without display of menu. Besides, the setting is made
impossible. (Basically, the menu is not displayed.)
•
The following keys become invalid:
•
Sound volume Up/Down (VOL +/–) [for both remote control and the unit]
•
Mute (MUTE)
Exception
•
In the item “VOLUME” of adjustment process, the sound volume can be set freely irrespective of this setting.
Remarks
•
As for sound volume fixing and sound volume MAX level, the sound volume fixing has priority.
•
Once the sound volume has been changed by adjustment process, it should be set back to the sound volume preset by
sound volume fixing level when the adjustment process ends.
Selection
Adjustment from 1 to 60 (no loop)
Default
20
Explanation
The sound volume to be fixed by “Volume fixed” is determined.
Limit in Setting
None
Exception
None
Remarks
Setting is valid only when “Volume fixed” is selected for “fixed”.
Selection
Selection between “Respond”, “No Respond” and “Limited” (loop provided)
Default
Respond
Explanation
Making the remote controller settings.
•
At the “No Respond” setting, the remote controller keys are disabled. Its power key (reception/standby key) is disabled too.
•
At the “Limited” setting, some channel-related keys alone are operative. All the other remote controller keys (power, volume
/
, channel
/
, light control (brightness sensor), broadcast select) are inoperative.
Limit in Setting
In “No respond” setting, all the keys (including the power key) are not accepted.
Exception
•
Adjustment process, inspection process and hotel only keys are valid irrespective of setting.
•
All the keys can be used in adjustment process, inspection mode and hotel menu irrespective of setting.
Remarks
Содержание Aquos LC-60SQ10U
Страница 46: ...LC 60 70EQ10U SQ10U 15U 17U TQ15U UQ17U 2 36 MEMO ...
Страница 89: ...LC 60 70EQ10U SQ10U 15U 17U TQ15U UQ17U ...
Страница 100: ...LC 60 70EQ10U SQ10U 15U 17U TQ15U UQ17U 2 1 LC 60EQ10U Service Manual CHAPTER 2 OPERATION MANUAL 1 OPERATION MANUAL ...
Страница 101: ...LC 60 70EQ10U SQ10U 15U 17U TQ15U UQ17U 2 2 ...
Страница 102: ...LC 60 70EQ10U SQ10U 15U 17U TQ15U UQ17U 2 3 ...
Страница 103: ...LC 60 70EQ10U SQ10U 15U 17U TQ15U UQ17U 2 4 ...
Страница 104: ...LC 60 70EQ10U SQ10U 15U 17U TQ15U UQ17U 2 5 ...
Страница 105: ...LC 60 70EQ10U SQ10U 15U 17U TQ15U UQ17U 2 6 ...
Страница 218: ...LC 60 70EQ10U SQ10U 15U 17U TQ15U UQ17U 7 4 MEMO ...