C-2
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
The unit will now have the correct DATA for the new MEMORY IC.
ADDRESS is now selected and should "blink". Using the UP/DOWN buton on the remote, step through the ADDRESS
until required ADDRESS to be changed is reached.
Press LEFT/RIGHT button to select DATA. When DATA is selected, it will "blink".
Again, step through the DATA using UP/DOWN button until required DATA value has been selected.
Pressing LEFT/RIGHT button will take you back to ADDRESS for further selection if necessary.
Repeat steps 4 to 6 until all data has been checked.
When satisfied correct DATA has been entered, turn POWER off (return to STANDBY MODE) to finish DATA input.
After the data input, set to the initializing of shipping.
Turn on the Power.
Set the VOLUME to minimum.
Press both VOL. DOWN button on the set and Channel button (1) on the remote control for more than 2 seconds.
After the finishing of the initializing of shipping, the unit will turn off automatically.
ADDRESS
DATA
INIT
0000 00
LCD ON 0000
ANALOG M : DB090_70605A
ANALOG S : DB0A0_70508A
FIG. 2
1.
2.
3.
Turn on the POWER, and set to the TV mode.
Set the VOLUME to minimum.
Press both VOL. DOWN button on the set and Channel button (6) on the remote control for more than 2 seconds.
ADDRESS and DATA should appear as FIG 2.
1.
2.
3.
4.
Version
Hardware version
A.0
Software version
CB00C76021
OK END
INIT : 2CE4
VCT-P : D92D LCD ON : 0000
ANALOG M : DB090_70605A
ANALOG S : DB0A0_70508A
FIG. 1
Turn on the POWER, and set to the TV mode.
Set the VOLUME to minimum.
Press both VOL. DOWN button on the set and Channel button (2) on the remote control for more than 2 seconds.
After the confirmation of MICON VERSION and Digital Firmware, turn off the power.
CONFIRMATION OF CHECK SUM, MICON VERSION, DIGITAL FIRMWARE AND POWER
ON TOTAL HOURS
Initial total of MICON VERSION, Digital Firmware and POWER ON TOTAL HOURS can be checked on the screen. Total
hours are displayed in 16 system of notation.
NOTE:
WHEN REPLACING EEPROM (MEMORY) IC
If you set a factory initialization, the total hours is reset to "0".
Please refer to "CONFIRMATION OF INITIAL DATA" when SUM DATA is not corresponding.
If a service repair is undertaken where it has been required to change the MEMORY IC, the following steps should be
taken to ensure correct data settings while making reference to INITIAL SETTING TABLE (Attached "INITIAL DATA").
CONFIRMATION OF INITIAL DATA
Initial setting data check sum.
POWER ON total hours.
= (16 x 16 x 16 x thousands digit value)
+ (16 x 16 x hundreds digit value)
+ (16 x tens digit value)
+ (ones digit value)
Digital
Soft
ware
SCALER data check sum.
NOTE: The each item value might be different according to each set.
Main Micon Firmware Version
Sub Micon Firmware Version
Digital
Hardware
NOTE:
No need to set data other position than 0D00~0E3F and 2000~7FFF.