AM-900U
2 – 19
SW
NO.
DATA
NO.
ITEM
Switch setting and function
Initial setting
Remarks
1
0
U
SW13
1
2
3
4
5
DTMF output level (High)
0
1
1
0
0
6
Reserved
0
7
Reserved
0
8
Reserved
0
SW14
1
2
3
4
5
DTMF output level (Low)
1
0
0
0
0
6
Reserved
0
7
Reserved
0
8
Reserved
0
SW15
1
2
3
4
V.34 mode transmission speed
1
1
1
0
5
6
7
8
V.34 mode receiving speed
1
1
1
0
SW16
1
Reserved
0
2
Reserved
0
3
Reserved
0
4
Reserved
0
5
Reserved
0
6
Reserved
0
7
Reserved
0
8
Reserved
0
SW17
1
Reserved
0
2
Reserved
0
3
Reserved
0
4
Reserved
0
5
Reserved
0
6
Reserved
0
7
Reserved
0
8
Reserved
0
Binary input
No. =
16 8 4 2 1
1
2 3 4 5 (Data No.)
EX 0
1 1 0 0
eg. Signal transmission level is set to -10dBm
Binary input
No. =
16 8 4 2 1
1
2 3 4 5 (Data No.)
EX 1
0 0 0 0
eg. Signal transmission level is set to -10dBm
Sending speed = 2400(bps) x n
Example:
2400(bps) x 12 = 28800(bps)
2400(bps) is set for N=0. 33600(bps) is set for N=15.
Receving speed = 2400(bps) x n
Example:
2400(bps) x 12 = 28800(bps)
2400(bps) is set for N=0. 33600(bps) is set for N=15.
Содержание AM 900 - Digital Office Laser Copier
Страница 120: ...AM 900U 6 13 13 Control PWB parts layout Bottom side The CONTROL PWB of the model employs lead free solder F3 F5 F7 F4 ...
Страница 122: ...AM 900U 6 15 2 LIU PWB parts layout Top side The LIU PWB of the model employs lead free solder ...
Страница 123: ...AM 900U 6 16 3 LIU PWB parts layout Bottom side The LIU PWB of the model employs lead free solder ...