CHAPTER 2. ELECTRIC CIRCUIT
[1] ELECTRIC PARTS
1. INDOOR UNIT (AH-MP20)
PART NO.
PART NAME
ITEM
SPECIFICATION
1
Terminal Board
Rating
300V,25A
2
Fan motor Capacitor
Rating
450V, 2
µ
F
3
Relay-1
Rating
AC250V,20A
(RY1)
Coil Volt: 12V
4
Printed Wiring Board
Material
Paper Base Phenolic Resin (UL 94V-0)
5
Transformer
Rating
Pri 220-240VAC
6
Fan motor
Rating
220 - 240VAC 50Hz 41W 4-Pole
Type
MLA999
Thermal Protector Cut off 135 10 C
(Internal)
7
Power Supply Cord
Rating
3 x 1.5 mm2
Type
H05VV-F
8
Louver Motor
Rating
DC12V
Type
24BYJ48
1. OUTDOOR UNIT (AU-MP20)
PART NO.
PART NAME
ITEM
SPECIFICATION
1
Terminal Board
Rating
300V,25A
2
Fan motor Capacitor
Rating
450V, 3
µ
F
3
Running Capacitor
Rating
400V, 45
µ
F
4
Compressor
Rating
AC220V 50Hz 1730W
Type
PH31VNET
5
Protector
Rating
-
Type
(INTERNAL)
6
Fan motor
Rating
220 - 240VAC 50Hz 71W 6-Pole
Type
MLA002
Thermal Protector Cut off 135 5 C
(Internal)
5
± °
± °
Содержание AH-MP20
Страница 3: ... 2 EXTERNAL DIMENSION 3 1 Indoor unit AH MP20 2 Outdoor unit AU MP20 ...
Страница 4: ...4 Indoor Unit AH MP20 Outdoor Unit AU MP20 3 WIRING DIAGRAM CC097 UNIT TO UNIT CORD ...
Страница 7: ...2 PRINTED WIRING DIAGRAM 1 Indoor AH MP20 7 ...
Страница 12: ...CHAPTER 4 TROUBLESHOOTING 12 ...
Страница 13: ...13 ...
Страница 14: ......
Страница 16: ...1 14 16 2 PERFORMANCE CURVES ...
Страница 21: ...3 The Drain pan and related 1 Remove the screw fixing the Drain pan on both side 2 Turn left the Drain hose 21 ...