background image

5

 

No.

Accessories

Q'ty

Right closure assembly
Left closure assembly
Window sash foam seal

1
1
1

1.   Screw driver (medium size Phillips)
2.   Tape measure or ruler
3.   Knife or scissors
4.   Cotton gloves

INSTALLATION INSTRUCTIONS

Screws(L=1", 25.4mm)

Top angle

7

1

9

Screws(L=

1

/

4

", 6mm)

Window sash foam seal
(adhesive type)

1

Battery

Remote control

2

1

Cut the window sash foam seal (adhesive type) to
the  proper length and attach it to  the underside  of
the window sash.

1

WARNING

: Make sure the unit is turned off and unplugged before working.

Wear cotton gloves when working on installation, in order to avoid injuries.

window sash foam seal
(adhesive type)

ITEMS PACKED WITH THIS UNIT

SUGGESTED TOOLS

INSTALLATION

1

2

3

4

5

6

7

8

9

!

"

5

$

%

&

'

Front panel

Exhaust Lever

(1)

2

Unscrew the 2 screws at the corners of
the front panel.  Keep them as they will
be used later.
Remove the front panel by pulling the
front panel at the lower corners towards
you about an inch.
Next lift it up and pull it towards you.

(2)

Move the exhaust lever and the 3 ver-
tical louver levers thoroughly to the left
when replacing the front panel.Take
care not to damage the levers.

CAUTION:

Front
panel

Horizontal

Louver

 Vertical louver lever

Содержание AF-R100EX

Страница 1: ...ING INSTRUCTIONS 8 NOTES ON OPERATION 9 ENERGY EFFICIENCY TIPS 9 HOW TO OPERATE PARTS NAMES 10 COOLING OPERATION 11 TO CHANGE FAN SPEED AND OPERATION MODE 11 TO CHANGE TEMPERATURE SETTING 12 TO CHANGE AIR FLOW DIRECTION 12 EXHAUST 12 ENERGY SAVER OPERATION 13 SLEEP OPERATION 13 ON TIMER OPERATION 14 OFF TIMER OPERATION 15 USING THE REMOTE CONTROL 16 CLEANING AND MAINTENANCE 18 BEFORE CALLING FOR S...

Страница 2: ...cer PARTS for your Authorized Parts Distributor ACCESSORIES ADDITIONAL CUSTOMER INFORMATION TO WRITE For service problems warranty information missing items and other assistance Sharp Electronics Corporation Customer Assistance Center 1300 Naperville Drive Romeoville IL 60446 1091 Please provide the following information when you write or call model number serial number date of purchase your compl...

Страница 3: ...ilities and responsibilities of Sharp to the purchaser with respect to the Product and shall constitute full satisfaction of all claims whether based on contract negligence strict liability or otherwise In no event shall Sharp be liable or in any way responsible for any damages or defects in the Product which were caused by repairs or attempted repairs performed by anyone other than an authorized ...

Страница 4: ...from stool to lower sash bottom must be 15 7 16 392mm or more The air conditioner should be installed on a firm foundation to minimize noise and vibration For safe installation repairs replacement and secure positioning make sure the the foundation is solid and level The room air conditioner must be installed in an area within reach of a properly rated grounded outlet Use of extension cords of any...

Страница 5: ... off and unplugged before working Wear cotton gloves when working on installation in order to avoid injuries window sash foam seal adhesive type ITEMS PACKED WITH THIS UNIT SUGGESTED TOOLS INSTALLATION 1 2 3 4 5 6 7 8 9 5 Front panel Exhaust Lever 1 2 Unscrew the 2 screws at the corners of the front panel Keep them as they will be used later Remove the front panel by pulling the front panel at the...

Страница 6: ... step make sure the cabinet is inclined approximately 1 cm 3 8 to the back If the cabinet is not properly inclined the water collected in the bottom tray during operation will not drain properly and may flow into the room where the air condi tioner is installed Unscrew the 5 stopper screws of the cabinet Keep the 3 screws from the front and side as they will be used later Slide the chassis out fro...

Страница 7: ...ween the horizontal louver and the front panel then hook the cabinet top 1 Window sash foam seal 2 3 10 Slide the chassis back into the cabinet Replace the 3 screws removed in step 3 to the Front and side of the cabinet 1 2 CAUTION 2 Cut the window sash foam seal to the proper length and seal the opening be tween the top of the inside window sash and the outside window sash 12 Horizontal Louver Fr...

Страница 8: ...pliances PRECAUTIONS 3 Pronged receptacle 3 Pronged plug Grounding prong Grounded receptacle box Grounding adapter Grounded receptacle box Screw Tab for grounding screw Grounding wire WARNING Improper use of the grounding plug can result in the risk of electric shock This appliance must be grounded In the event of an electrical short circuit grounding reduces the risk of electric shock by providin...

Страница 9: ...ifference between the inside and outside temperature within 10 F 5 C Do not keep the temperature setting any lower than is necessary for you to feel comfortable Generally 78 F to 80 F 26 C to 27 C is a comfortable summer indoor temperature When you turn the unit on do not set the temperature higher than the room temperature at start up as this will not allow the compressor to cycle and maintain a ...

Страница 10: ...andle Filter Pull the filter handle to the right to remove Power cord PARTS NAMES Receiver window for remote control signal Display SLEEP indicator SELECTOR pad COOL indicator TEMPERATURE setting pad Lower temp Raise temp TIMER ON OFF pad TIMER indicator ENERGY SAVER pad ENERGY SAVER indicator POWER ON OFF pad POWER indicator 1 2 3 4 5 6 7 8 9 10 11 12 13 hr F POWER ON OFF ENERGY TIMER SAVER ON OF...

Страница 11: ... OPERATION TO CHANGE FAN SPEED AND OPERATION MODE During operation Touch SELECTOR pad and select the operation mode and fan speed Fan speed and operation mode will change as you touch NOTES ON OPERATION MODE COOL indicator DISPLAY HIGH COOL MED COOL LOW COOL HIGH FAN MED FAN LOW FAN When the SELECTOR is changed to fan only operation from cooling operation it will take 5 seconds for the compressor ...

Страница 12: ...er must touch POWER ON OFF to resume operation During cooling operation TO CHANGE TEMPERATURE SETTING Raise temp hr F POWER ON OFF ENERGY TIMER SAVER ON OFF SELECTOR TEMP COOL SLEEP TO CHANGE AIR FLOW DIRECTION Horizontal louvers Adjust UP DOWN air flow The horizontal louvers are used to adjust the UP DOWN direction of air flow and the vertical louvers are used to adjust the LEFT RIGHT direction o...

Страница 13: ... SLEEP OPERATION When SLEEP OPERATION is set the temperature setting is automatically adjusted to prevent the room from becoming too cold while you sleep One hour after the SLEEP OPERATION is started the temperature setting rises 2 F higher than the original temperature setting The temperature will return to its original setting after 8 hours Temperature display on the unit will not change from it...

Страница 14: ...l start when the set time expires The temperature setting will be displayed This unit has a built in timer that can be programmed to start the unit up to 12 hours in advance You can set the timer to start in increments of 30 minutes 0 5 hours up to 9 5 hours in advance of the start time or in 1 hour increments from 10 to 12 hours in advance of the start time The unit will start automatically accor...

Страница 15: ... you wish to stop the operation 10 hours later set the delay time as shown above TO CANCEL THE TIMER SETTING Touch the TIMER ON OFF pad again after the timer is set or press the TIMER ON OFF pad until CL cancel appears on the display When the unit is operating NOTES FOR ON OFF TIMER SETTING AND OPERATION After setting the TIMER change the temperature and fan speed settings as shown on pages 11 and...

Страница 16: ...towards the unit s re ceiver window and press the desired button A beep will sound when the unit receives the signal Make sure no objects such as curtains block the receiver window The remote control operates from up to 20 feet 6 meters away The beep will also sound when each pad on the control panel is touched CAUTION Do not expose the receiver window to direct sunlight This can adversely affect ...

Страница 17: ... to cancel the timer push the OFF TIMER button again after the time is set or push the OFF TIMER button until CL cancel appears on the display A double beep will sound when the timer is cancelled The ON TIMER cannot be set with the remote control It can only be activated by the TIMER ON OFF pad on the unit s control panel See page 14 SLEEP button Push to start or cancel the SLEEP OPERATION See pag...

Страница 18: ... handle and gently push the filter back into place Never operate the unit without installing the filter It may result in serious damage to the unit 1 CLEANING OF THE FRONT PANEL AND CABINET To clean the front panel and cabinet wipe with a soft dry cloth or with a cloth moistened with a mild soap Rinse carefully by wiping with a damp cloth and dry completely Avoid splashing the unit with water Exce...

Страница 19: ...rtains or blinds to minimize solar energy heating the room Are the windows or doors open Close all windows and doors for maximum cooling TIMER DOES NOT WORK PROPERLY If a power failure occurs while the ON or OFF TIMER is set the TIMER setting will be cancelled and will not resume even after the power is reinstated This is the normal operation for this unit NOTE WATER IN BOTTOM OF TRAY Water will c...

Страница 20: ...20 SHARP ELECTRONICS CORPORATION Sharp Plaza Mahwah New Jersey 07430 2135 SHARP CORPORATION Osaka Japan Printed in Thailand ...

Отзывы: