background image

The unit must only be installed by authorised air conditioner contractors according to municipal 
or government regulations and  in compliance wi th this manual.

The unit should be installed with a dedicated electrical circuit, and a circuit breaker should 
be fitted in accordance with regulations.

Proper installation position is vital for correct and efficient operation. Avoid the 
following positions:

liquids

electro-magnetic 

Where salt-laden air is a problem (such as close to coastal areas).

Where the air is contaminated with industrial vapours and oils.

Where the air contains sulphured gas such as in hot spring zones.

environments where corrosion or air quality is a problem.

away from any obstruction. Ensure the air can be 

blown through the whole room.

easily connected to the outdoor unit.

where it is 

the wall 

is installed in accord with the installation instructions.

which will 

is installed in accord with the installation instructions, 

and is convenient for maintenance and repair.

between indoor and outdoor units is within 5 metres, and the length

 of the connecting tubing does not exceed 10 metres.

which

pedestrian

1.8m above the floor.

Содержание AE-X09MCJ

Страница 1: ...ouforselectingSHARPair conditioner Pleaseread this manual carefully before operation and keep it for further reference Split Type Inverter Room Air Conditioner MODELS AY X09MCJ AE X09MCJ AY X12MCJ AE X12MCJ AY X18MCJ AE X18MCJ ...

Страница 2: ......

Страница 3: ...be separated for special treatment as required by local regulations and cleaning ing ing that should be prevented that Specifications NOTE All the pictures in this manual are just schematic diagrams The actual product is the standard ...

Страница 4: ......

Страница 5: ...1 5 ...

Страница 6: ...mals and plants directly to the output air flow as it may have a detrimental effect on them Don t expose yourself to cold output airfor prolonged periods as it may affect yourphysical condition This air conditioner is designed for normal residential use Do not use for any other purpose such as food preservation or drying clothes Don t place a space heater or cooking appliances near the air conditi...

Страница 7: ...rom outdoors and transmit it to the indoor unit increasing room temperature Heating capacity will decrease in lower ambient temperatures When outdoor temperature is low but high humidity frost may form on the outdoor unit during extended operation affecting heating efficiency The air conditioner operation may stop for 8 10mins during auto defrosting function During auto defrosting the indoor indic...

Страница 8: ...Name and function of each part X FAN ...

Страница 9: ...peed is default when unit switched on AUTO Press this button to set clock function the clock symbol will blink and display Within 5 seconds the time can be adjusted by pressing or button Press button continuously for rapid time change During blinking press confirm button or clock button again to complete time setting Press this button to select between Auto Cool Dry Fan and Heat modes Auto mode is...

Страница 10: ...ssing and holding for 2 seconds changes the temperature rapidly The temperature adjustment is unavailable under the Auto Mode Press this button to turn light On or Off Light On is defau lt when unit is switched on Press this button to select or cancel mode off is default when unit is switched on Under Cool or Heat mode pressing this button turns on or off the Turbo function After the turbo functio...

Страница 11: ...re than 2 seconds changes the time rapidly While time is blinking press Timer On button to confirm setting After setting repressing the Timer On button cancels the operation symbol is displayed the remote control will send a temperature reading to the wall unit every 10 minutes Press the I FEEL button again to cancel operation When the I FEEL sel ect The functions below are not applicable to this ...

Страница 12: ...unit odels m to switch the fan will con tinue to after the unit is stopped to remove the function is not operated senses the room temperature automatically to select a suitable running method for room comfort TURBO hen TURBO mode is selected W X FAN X FAN X FAN X FAN X FAN x fan ON OFF ON OFF ...

Страница 13: ...t is switched off by the remote control If settings are changed they will only be carried out after defrosting is finished To turn defrost function On or Off press Mode button and button simultaneously when remote control is powered off When s selected i pressing switched off emove the battery cover plate from the rear of the remote control As shown in the figure R Replace the battery cover plate ...

Страница 14: ... be changed on the To operate Press the AUTO STOP button and the unit will enter into AUTO RUN mode The microcomputer will monitor the room temperature to select the COOL HEAT FAN mode automatically to obtain the comfortable effect To turn off Press the AUTO STOP button to switch the unit off ...

Страница 15: ...ront panel remove by pulling forwards Some minor force may be required LCD display if fitted from the front panel Before cleaning remove the Align and insert the two support lugs of the front panel into the slots then rotate downwards as shown in the figure It is recommended to clean the filters every three months More frequent cleaning is required in dusty environments After removing the filters ...

Страница 16: ...ove from the unit water temperature should be and leave to dry naturally in a shady location it with a heater or open flame as fire or deformation may occur Never dry in the direction of the arrows then close the front panel Never operate the unit if the wiring or connections have been damaged report to a licenced contractor ...

Страница 17: ...smell has been accumulated from the environment clean the air filter If smells persist contact your Approved Service Centre to arrange cleaning fluid gurgling noises This is not a fault it is the sound of flowing refrigerant mist nd or contraction a cracking sound mist ...

Страница 18: ...erence near the main unit that may be affecting the operation of the controller Is the wireless remote control within its operating range or obstructed Check the condition of the batteries and replace if necessary has overflowed has been loosened water condensation occurs naturally around the pipe and connections some ice has thawed and flowed out water adhered on the heat exchanger has dripped ou...

Страница 19: ...ion water or vapour may be emitted frost can be formed disconnect from the power supply and report to an authorised air conditioner contractor in the following situations Strong odours are emitted Circuit breaker continuously trips off Water has dripped into or been splashed onto the unit Power leads or connections have been damaged isconnect from d power supply ...

Страница 20: ...ose to coastal areas Where the air is contaminated with industrial vapours and oils Where the air contains sulphured gas such as in hot spring zones environments where corrosion or air quality is a problem away from any obstruction Ensure the air can be blown through the whole room easily connected to the outdoor unit where it is the wall is installed in accord with the installation instructions w...

Страница 21: ... rules A circuit breaker should be installed WARNING inadequate or incorrect electrical connections may cause electrocution or fire lease ensure the the unit is reliably earthed P the air conditioner is the earthing wire and cannot be used for any other purpose Improper earthing may cause electrocution The unit must be reliably earthed in accordance with AS NZS3000 AS NZS3000 and your electrical s...

Страница 22: ...e Above Above Space to the wall Space to the wall Space to the wall Above Above A b o v e m c 0 3 50cm 0 2 0 15cm 15cm 300 cm 2 15 cm Space to the floor Air outlet side Space to the obstruction Air outlet side Air inlet side A b o v e m c 0 2 m c 0 Above 30cm Above cm cm 230 Installation dimension diagram ...

Страница 23: ...he electrical connection cover plate and screw hole in the provided replace the using Replace sing U Installing the indoor unit and leveled to ensure correct drainage Fig 1 Rear piping hole Rear piping hole Left Right Mark on the middle of it Gradienter Space to the wall 150mm above Space to the wall 150mm above Wall Wall ...

Страница 24: ...lectrical connections are properly earthed to prevent electrical shocks Ensure all wiring connections are secure and the cover plates are reinstalled properly Poor installations that allow dust or moisture incursion may cause fire or electrocution A circuit breaker of adequate capacity should be installed at the switchboard output Nm ensure the joint nut is adequately tightened Installing the indo...

Страница 25: ... connection access plate either right hand side or front from the outdoor unit Replace access plate either right hand side or front on the outdoor unit Incorrect unit failure has been fitted Installing the Outdoor Unit ...

Страница 26: ...soapy gas detection are leaking Outdoor attach satisfactorily Installing the Outdoor Unit ...

Страница 27: ...satisfactory to the product product Are the inlet and outlet air openings blocked Is the quantity of gas charge sufficient for the length of pipe run may be insufficient ...

Страница 28: ... l h 0 8 EER C O P W W 4 25 4 22 Energy Class A A Model of Indoor Unit AY X09MCJ Fan Motor Speed r min SH M L 1350 1100 950l 820 Output of Fan Motor w 10 Fan Type Piece Cross flow fan 1 Diameter Length mm φ85 X 668 Evaporator Aluminum fin copper tube Row Fin Gap mm 2 1 5 Coil length l x height H x coil width L 657X285X25 4 Swing Motor Model MP28VB Output of Swing Motor W 2 Fuse A PCB 3 15A Transfo...

Страница 29: ...rpm 830 20 Output of Fan Motor W 30 Liquid line diameter mm Gas line diameter mm Air Flow Volume of Outdoor Unit m3 h 1800 Fan Type Piece Axial fan 1 Fan Diameter mm 400 Defrosting Method Auto defrost Climate Type T1 Isolation Moisture Protection IP24 Permissible Excessive Operating Pressure for the Discharge Side MPa 3 8 Permissible Excessive Operating Pressure for the Suction Side MPa 1 2 Sound ...

Страница 30: ...fying Volume l h 1 2 EER C O P W W 3 51 3 61 Energy Class A Model of Indoor Unit AY X12MCJ Fan Motor Speed r min S H M L 1400 1150 1050l 900 Output of Fan Motor w 10 Fan Type Piece Cross flow fan 1 Diameter Length mm φ85 X 668 Evaporator Aluminum fin copper tube Row Fin Gap mm 2 1 5 Coil length l x height H x coil width L 657X285X25 4 Swing Motor Model MP28VB Output of Swing Motor W 2 Fuse A PCB 3...

Страница 31: ...ed rpm 830 20 Output of Fan Motor W 30 Air Flow Volume of Outdoor Unit m 3 h 1900 Fan Type Piece Axial fan 1 Fan Diameter mm 400 Defrosting Method Auto defrost Climate Type T1 Isolation I Moisture Protection IP24 Permissible Excessive Operating Pressure for the Discharge Side MPa 3 8 Permissible Excessive Operating Pressure for the Suction Side MPa 1 2 Sound Pressure Level dB A H M L 54 Sound Powe...

Страница 32: ...Energy Class A Model of Indoor Unit AY X18MCJ Fan Motor Speed r min H M L 1200 1050 900 1250 1150 1000 Output of Fan Motor w 20 Fan Type Piece Cross flow fan 1 Diameter Length mm φ96 X 797 Evaporator Aluminum fin copper tube Row Fin Gap mm 2 1 6 Coil length l x height H x coil width L 785X340 51X25 4 Swing Motor Model MP35XX Output of Swing Motor W 2 5 Fuse A PCB 3 15A Transformer 0 2A Sound Press...

Страница 33: ...f Fan Motor W 60W Air Flow Volume of Outdoor Unit m3 h 2700 Fan Type Piece Axial fan 1 Fan Diameter mm 460 Defrosting Method Auto defrost Climate Type T1 Isolation I Moisture Protection IP24 Permissible Excessive Operating Pressure for the Discharge Side MPa 3 8 Permissible Excessive Operating Pressure for the Suction Side MPa 1 2 Sound Pressure Level dB A H M L 56 54 52 Sound Power Level dB A H M...

Страница 34: ...H IUHLJKW FKDUJHV WR DQG IURP D 6KDUS SSURYHG HQWUH RU WUDYHOOLQJ FKDUJHV LI UHTXLUHG 7 55 17 6 68 7 72 7KH XQLW LQVWDOOHG LQ DFFRUGDQFH ZLWK RXU QVWDOODWLRQ QVWUXFWLRQV 7KH XQLW PXVW EH LQ D VHUYLFHDEOH DUHD ZLWK WKH 2XWGRRU XQLW QR KLJKHU WKDQ P DERYH JURXQG OHYHO 7KH ZDUUDQW LV DSSOLFDEOH WR WKH RULJLQDO LQVWDOODWLRQ RQO 7KH XQLW KDV EHHQ LQVWDOOHG E DSSURSULDWHO OLFHQVHG FRQWUDFWRUV 7 25 2 1 5...

Страница 35: ... 09 573 0113 FOR LOCATION ENQUIRIES WITHIN AUSTRALIA REGARDING YOUR LOCAL SHARP APPROVED SERVICE CENTRE VISIT OUR WEBSITE AT www sharp net au OR CALL SHARP CUSTOMER CARE 1300 135 022 SHARP CORPORATION OF AUSTRALIA PTY LTD SPform019 Oct2006 LOCAL CALL COST APPLY WITHIN AUSTRALIA SHARP APPROVED SERVICE CENTRE www sharp net nz CONTACT YOUR SELLING DEALER RETAILER OR CALL SHARP SHARP ...

Страница 36: ...66129905916 SHARP CORPORATION OF AUSTRALIA PTY LTD ABN 40 003 039 405 1 Huntingwood Drive HUNTINGWOOD NSW 2148 www sharp net au ...

Отзывы: