Model
AY-X09MCJ
;
AE-X09MCJ
Function
COOLING
HEATING
Rated Voltage
220
-
240V
Frequency(Hz) (High/Standard *)
50HZ
Total Capacity (W) (High/Standard *):
Total Capacity (Btu/h) (High/ Standard *):
3300/2600/ 1188(W)
11200/9000/4063(Btu/h)
3800/2850/1109 (W)
13000/9800/3792(Btu/h)
Power Input (W) (High/ Standard*)
1200/610/264
1250/670/230
Rated Input (W) (High/ Standard *)
1200
1280
Rated Current (A) (High/ Standard *)
5.5
6.0
Air Flow Volume (m
3
/h)
(H/M/L)**
450
Dehumidifying Volume (l/h)
0.8
EER / C.O.P (W/W)
4.25
4.22
Energy Class
A/A
Model of Indoor Unit
AY-X09MCJ
Fan Motor Speed (r/min) (SH/M/L)
1350/1100 /950l/820
Output of Fan Motor (w)
10
Fan Type-Piece
Cross flow fan – 1
Diameter-Length (mm)
φ
85 X 668
Evaporator
Aluminum fin-copper tube
Row-Fin Gap(mm)
2-1.5
Coil length (l) x height (H) x coil width (L)
657X285X25.4
Swing Motor Model
MP28VB
Output of Swing Motor (W)
2
Fuse (A)
PCB 3.15A Transformer 0.2A
Sound Pressure Level dB (A)
(S/H/M/L)
42/ 38 / 30/28
Sound Power Level dB (A) (S/H/M/L)
53/ 47/ 40/38
Dimension (W/D/H)( mm)
872X178X283
Dimension of Package
(W/D/H)( mm)
935x260X375
Indoor
unit
Net Weight /Gross Weight (kg)
12/15
Specifications
- 24 -
Содержание AE-X09MCJ
Страница 2: ......
Страница 4: ......
Страница 5: ...1 5 ...
Страница 8: ...Name and function of each part X FAN ...
Страница 26: ...soapy gas detection are leaking Outdoor attach satisfactorily Installing the Outdoor Unit ...