User’s Guide
HRT 65-125
-
5
-
hs
Technische Daten
type
HRT 65
HRT 125
Assembly
Control unit
Max.
2
4
Heating element
Max
2, fitted with single
filament
4, fitted with single
filament
Electrical
Control unit
Voltage
220
– 240 V AC
Power
300 VA
500 VA
Fuse
2,5 AT x2
5 AT x2
max. power:
600VA
2000 VA
connection
CEE 7/4 16A 2P+A
Filament
0-17 V, 0-13 A ~
0-30 V, 0-13 A ~
Network connection
CEE 7/4 16A 2P+A
Network circuit breaker
16 A
Mechanical
Gradation of stop
0-640 mm
dimensions
[LxWxH]
835 x 680 x 160 mm
1470 x 850 x 160 mm
weight
40 Kg
60 kg
**
Lifetime filament
±500 hours
Functional
Bending width
600 mm
1250 mm
Mutually extendible*
20-465 mm
20 - 610 mm
Sheet thickness*
1 - 5 mm
Temperature filament
Max
20-
550 ◦C
Filament height
adjustment
1 - 6 mm
Ambient
Temperature
18-30
C
Humidity of the air
50-80 % (no condensed)
Miscellaneous
set of socket screws
keys
1 set [1½, 3, 5 mm]
Spare fuse
4 x [6.3x32 2,5 AT]
each controller
4 x [6.3x32 5 AT] each
controller
Spare filament
1 x [
0.9 x 750 mm]
per element
1 x [
0.9 x 1350 mm]
per element
* Depends on the heating element
** Depends on the amount of controllers
2