www.shakmat.com
•
24/26
Now let's place the
module in your system
and test it. Plug in the
power cable and make
sure the red side
matches the -12V on
the PCB. We recom-
mend you to start the
module in Full calibra-
tion mode. To do so,
hold the CNFG button
pressed whil powering
on the module.The
SYNC LED should
start to blink. If so
continue to the next
chapter. If the LED is
not responding, turn
your system off and
on again to re-start the
module in normal mode. Press the mode button and the first mode LED
should blink or be on. If no LED is on or blinking, the module is probably not
powering up. You might re-check the power cable orientation, the orientation
of all the LEDs, electrolytic capacitors and the Tactical Plan. If everything is
correctly oriented, double check all your solder points.
8. Powering
Your module has a blinking SYNC LED ? So, it’s in Full calibration mode. This
mode consists ot two chained calibration procedure: the Time potentiometer
calibration and the CV inputs calibration. Before starting the procedure, make
sure that no cable is plugged in the Aeolus Seeds.
First, you have to set the Time potentiometer to every blank spot of the front
panel print around the potentiometer, and press the Sync button once. So,
adjust the Time potentiometer on the empty spot between the x3 and x2 zones
of the left side and press the SYNC button. Then, adjust the potentiometer on
the empty spot between the x2 and x1 zones, and press the SYNC button again.
9. Calibration
-12V
Shakmat
Aeolus Seeds
Содержание Aeolus Seeds
Страница 1: ...Shakmat AeolusSeeds BuildingGuide 10HP Eurorack Module Built designed in Belgium www shakmat com...
Страница 5: ...www shakmat com 04 26 3 PCB details Top PCB Front back 12V...
Страница 6: ...www shakmat com 05 26 Tactical Plan Front back Bottom PCB Front back Shakmat AeolusSeeds...
Страница 28: ...www shakmat com...