TECHNICAL DATA

 

4/12

TECHNİCAL SPECIFICATION

OEK-400

TOTAL ELECTRICAL INPUT (kW) 

1,9

SUPPLY VOLTAGE (VAC) 

220/240

WORKING FREQUENCY (Hz) 

50/60

POWER SUPPLY CABLE (Number of cores x  mm²) 

3x1,5

DIMENSIONS (Width-Length-Height) (mm) 

440x400x340

BENCH HEIGHT (mm) 

850

MAXIMUM SLOPE 

5 °

CLASS 

1

PROTECTION CLASS 

IP 20

CAPACITY (slices per hour) 

420

Содержание Trio OEK-400

Страница 1: ...PRODUCTION YEAR SERIAL NO 2009 Published on 23 01 2004 VER V11 7 Page1 of 12 CONVEYOR TOASTER OEK 400 USER S AND MAINTENANCE MANUAL 1 2...

Страница 2: ...ARNING SIGNS 6 SAFETY DETAILS 7 TRANSPORTING AND MOVING 8 9 INSTALLATION OF THE DEVICE AND ELECTRICAL CIRCUIT DIAGRAM 10 11 OPERATION OF THE DEVICE 12 TERMS OF GUARANTEE 2 12 CAUTION This device shoul...

Страница 3: ...r you don t have enough information please get in touch with authorized service by phone Please keep in mind that if the service personnel is delayed at your site related expenses and delay costs will...

Страница 4: ...TRICAL INPUT kW 1 9 SUPPLY VOLTAGE VAC 220 240 WORKING FREQUENCY Hz 50 60 POWER SUPPLY CABLE Number of cores x mm 3x1 5 DIMENSIONS Width Length Height mm 440x400x340 BENCH HEIGHT mm 850 MAXIMUM SLOPE...

Страница 5: ...WARNING SIGNS POWER NETWORK GROUNDING PE GROUNDING OVERHEAT SUPPLY CONNECTION MONOPHASE GROUNDED POWER 5 12 VOLTAGE 220 240V NPE 50 60 Hz...

Страница 6: ...ot be handled by anyone else except for the manufacturer or authorized service 6 12 The device should not be exposed to direct air flow 5 C 40 C Supply voltage of the device is 220 240V 50 Hz Do not u...

Страница 7: ...m the power supply The vehicle can be moved with manpower Do not hit or drop the device when moving 7 12 1 2 Machines installed by an authorized service CANNOT BE MOVED ELSEWHERE ITS POWER SUPPLY CABL...

Страница 8: ...nds should be adjustable and leveled with balance Power connections should be checked by an eligible electrician and the device should be connected to a fuse at 400 mm high above the ground Power inst...

Страница 9: ...RCUIT DIAGRAM 9 12 S1 Commutator S2 Rate setting button BTH Upper resistance TH Lower resistance M1 Motor M2 Fan S1 Commutator S2 Rate Setting Button RA Lower Resistance RU Upper Resistance M1 Motor M...

Страница 10: ...e time relay After disconnecting from power supply clean the device up It is recommended to operate the device between temperatures of 5 C 40 C and in ambient humidity of maximum 65 This part shows to...

Страница 11: ...oes not operate after those checks call your authorized service dealer LIFE OF USE Devices life of use is 10 year if it is used under recommended conditions CLEAN UP AND MAINTENANCE Clean up and maint...

Страница 12: ...on about the kind and the type of the device serial numbers printed on the guarantee document are scraped rubbed or changed then the guarantee is not valid 6 The guarantee covers only maintenance and...

Отзывы: