17
Giotto Spot 400 CMY rel.1.00
Control Microcomputer
GB
Menu
Options
Description
Addr=xxx
Range 001-480
Fixture addressing
NORM
Normal PAN control of left to right PAN movement.
Pmove
REV
Inverted PAN movement control (from right to left).
PP_min
Range 000-536
Sets PAN movement start position.
Default configuration = 000 degrees
PP_max
Range 004-540
Sets PAN movement stop position.
Default configuration = 000 degrees
NORM
Normal control of TILT from up to down.
Tmove
REV
Inverted TILT movement control (from down to up).
TP_min
Range 000-236
Sets TILT movement start position.
Default configuration = 000 degrees
TP_max
Range 004-270
Sets TILT movement stop position.
Default configuration = 000 degrees
ON
Data regarding Pan controls Tilt and vice versa.
Swap
OFF
Normal control of Pan and Tilt movement.
Lmp_H
-
Read-only Menu. Stores lamp elapsed time. Can be reset.
Lmp_st
-
Read-only Menu. Stores the number of lamp strike. Can be reset.
SCN_h
-
Read-only Menu. Stores fixture operating time.
DMX
DMX signal selected
SIGN
RS-232
RS-232 signal selected
SMD
16 bit
8 bit
Enables selection of movement resolution.
Default configuration = 16 bit
GMD
16 bit
8 bit
Enables selection gobo indexing resolution.
Default configuration = 8 bit
EN
Remote lamp ignition enabled.
LMP_ctr
DS
Remote lamp ignition disabled.
EN
Remote reset enabled.
RST_ctr
DS
Remote reset disabled.
Speed
100% - 92%
84% - 76%
Allows to slow maximum Pan and Tilt speed.
Default configuration = 100%
Fast
Optimises speed performance.
Accel
Slow
Optimises smooth movement
Bright
100-53-40-27
20-13-6-0(%)
Allows adjustment of display brightness.
Default configuration =40%
DsplFlip
-
Inverts display reading position. Used according to the position in which the fixture is installed.
Range 8-998sec
It’s possible to set the number of second for which the fixture’s last operating status must be held
when there is no DMX signal.
(default =UNL )
DMXdly
UNL
Always maintains the fixture’s last operating status no matter for how long there is no DMX signal.
CSHUTT=DS
Disables shutter closure in the event of loss of position
CSHUTT
CSHUTT=EN
Enables shutter closure in the event of loss of position
FACT=SET
Enables to set default parameters
FACT
FACT=OFF
FACT Value during normal operation
PREV=SET
Enables to restore the values of the parameters set immediately before FACT=SET procedure
PREV
PREV=OFF
PREV value during normal operation
COL=1200
Enables to set the offset for calibrating the starting position of the colour wheel
GOB1=2000
Enables to set the offset for calibrating the starting position of the gobo wheel 1
GOB2=2000
Enables to set the offset for calibrating the starting position of the gobo wheel 2
RGOB1=1100
Enables to set the offset for calibrating the starting position of the rotating gobos
SETTING
RGOB2=1100
Enables to set the offset for calibrating the starting position of the rotating gobos
TEST=RESET
Fixture RESET.
TEST=ALL
TEST=PAN
TEST=TILT
TEST=COLOR
TEST=GOBO1
TEST=GOBO2
TEST=RGOB1
TEST=RGOB2
TEST=SHUTT
TEST=DIMM
TEST=FROST
TEST=FOCUS
TEST