18
Preparing for installing the ceiling mount
The ceiling mount bracket consists of two main parts:
•
the trapeze shaped mounting plate.
•
the ceiling plate.
After detaching the base of the fixture from the head, prepare the ceiling mount:
1.
Remove the two lock-screws (if installed) and separate the two parts.
2.
Remove the wire harness from the trapeze mounting plate (if installed) in order to expose the four holes. The four holes
will be used to start attaching the head to the ceiling mount.
Attaching the ceiling mount bracket to the fixture
1.
Align the mounting bracket to the head (the hub), so all four screws and the pilot holes are aligned.
2. Mount the bracket.
3.
Insert the four screws, tighten with 1Nm of torque.
4.
Mount the wire harness to the bracket, ensure the connector is properly fitted.
5. Insert the four screws, tighten with 0,6Nm of torque.
NB! Carefully observe that the orientation of the pilot hole on the ceiling mount bracket matches the pilot hole on the head
unit (see step 1 in the image below).
Installing the ceiling mount bracket
1.
Securely mount the base plate to the surface using the 4 oval shaped holes.
2.
Remove the lock-screws from the trapeze shaped head part (if installed).
3. Position the trapeze shaped head part over the four slide-locks and slide to the locked state.
4.
Install the two lock-screws to secure the parts from sliding off.
5.
Attach a safety wire between the head part and a secure location.
1
2
3
4
5
Saftety wire attachment point
Figure 13: Attaching the ceiling mount bracket