Checks before use:
4.1 Oil filling and checking
NOTE:
The generator is delivered without oil.
Do not attempt to start the
generator without adding oil in the engine first!
The generator has to be on a perfectly flat surface and levelled, to avoid an error
in the oil level reading.
1. Unscrew and remove the 4 screws (
A
) from the maintenance cover.
2. Remove the maintenance cover (
B
).
3. Remove oil cap (
C
), turning counter clockwise.
4. Using a funnel put the correct amount of oil (0,28L).
Use good quality four-stroke engine oil SAE10W30 or SAE10W40.
Recommended oil classification must be API
“SJ” (USA) or ACEA “A3” (EUROPA)
or more updated (See container specifications).
NOTE:
The engine may consume a bit of oil during its running. Therefore,
before each running, always check oil level and refill if necessary.
NOTE:
Never use oils that are old, dirty, in poor condition or without
specifications (grade and quality). Do not mix different types of oils.