1) General:
This appliance is a device developed according to the rules of art and
subjected to continuous quality control. These performances require
strict compliance with the installation and maintenance rules brought in
this and in particular the indications marked by:
Note that failure to comply could result in risks to the safety
of persons.
Warning indication of the presence of a risk of electrical origin.
This appliance is not intended for persons (including children) whose
physical, sensory or mental capabilities are limited, or which experience
and knowledge are defects, unless they are under supervision and
receive the necessary instructions for use the device with the help of a
person responsible for their safety. Supervise children and ensure they
do not play with the appliance.
2) Application:
This appliance is for domestic use only: fig. 1.
You will find equivalents height / length fig. 2.
Note: Each bend placed on the evacuation reduces the lifting capacity
of about 50 cm per elbow.
3) List of parts supplied:
See fig. 3.
4) Dimensions and dimensions:
See fig. 4.
5) Technical data:
Consumption:
470 W
Frequency:
50 hz
Voltage:
230-240 V
Protection degree:
IP 44
6) Electrical installation:
Do not electrically connect the end of the
installation.
The installation should be performed by qualified personnel and
installation must comply with current standards in the country.
- If the cable is damaged, it must be replaced by the manufacturer or
his Customer Service in order to avoid a hazard.
- Class I the equipment must be connected to a socket 2 poles +
earth.
- The socket must be used exclusively for the unit and power must
be connected to a 30 ma differential circuit breaker and fused 5 A.
7) fitting the side caps: fig. 5
- Insert the conical seal (J) on the cap (K) according to the indicated
direction (the thickest part of the seal must be in contact with the cap
range)
- Insert as indicated, all “top - cone joint” in the nut (L).
- Screw the entire assembly on the side inlets of the tank, to exert a
clamping to properly compress the seal.
8) Connecting to input side: fig. 6
- Unscrew
the
nut
(L)
of
the
connector
and
removing
the
plug
assembly
(K,
J).
- Place the PVC pipe Ø 40 in the nut (L) with its conical seal (J)
tighten the assembly to the connector.
All elements connected to the side entrances should result above the
level of reflux and have a drop of 130mm minimum: fig. 7.
9) connection of entry sink: fig. 8
The sink can be connected in 2 ways:
- Either on one of the side entrances
- Either the pre-entry cuttable cover:
Using a knife, remove the pre-cut cover, mount the connector (B) with
a collar (C1) on the entrance of the lid, place the drain of the sink Ø 40
mm in fitting (B) and tighten the clamp (C2)
Any device connected to the unit must be completely sealed. Even a
small leak causes unexpected start.
The
unit
may be fixed to the floor: fig. 10.
10) Connection to escape: fig. 11
- Fit the discharge elbow (A) and point it in the direction drainage,
tighten the elbow on the device with a collar (C1).
- Connect the drain Ø32 with a collar (C2).
In case of lifting, we recommend the installation of a second non-return
flap valve on the discharge line, closest to the appliance.
Warning !!!
•
Respect a 1% slope.
•
Avoid low spots.
11) Use and precautions:
Warning !!!
In case of prolonged absence (vacation), it is imperative to shut
off the main water supply to the house.
Any commercial or industrial application is prohibited.
Each power-up, the unit starts up 5 seconds. The appliance starts
automatically once a certain water level is reached in the tank.
12) Maintenance:
For cleaning and descaling, use conventional descaling sanitary
products.
To prevent scale buildup inside the unit, it is advisable to perform
regular descaling:
- Disconnect the appliance,
- Add a dose of descaling agent diluted in 3 or 4 liters of water,
- Let stand several hours,
- Reconnect, rinse.
Repeat 2 or 3 times a year.