EN
10
1. SAFETY
• These operating instructions contain
essential instructions that must be
observed during installation, operation and
maintenance.
•
Only use the pump in the fields of
application described in this documentation.
• The pump must only be operated in
technically perfect conditions.
•
The pump must only pump the fluids
described in this documentation.
•
Never exceed the usage limits defined in
the documentation.
• The safe operation of the pump is only
ensured if it is used as described in this
manual.
•
Any alteration or modification of the
pumping station will render the warranty
void. Use only genuine parts. The use of
other parts may void the manufacturer's
liability for any resulting damage.
•
Identification of warnings:
High risk of danger, due to vot-
tage, which can lead to death or
serious injury, if not avoided.
Danger to the machine and its pro-
per operation.
2. DECRIPTION
2.1 AREA OF APPLICATION
Sanipuddle
is suitable for conveying slightly
contaminated water with suspended solids (no
rocks) from private households or commercial use.
The size of suspended solids
must
not exceed
1 mm.
NOTICE
Ö
The pump must not be used to convey
waste waters containing substances
which attack or damage the pump’s
materials.
Ö
The pump is not approved for conveying
waste waters containing faeces.
2.2 TECHNICAL DATA
Power rating P1
300 W
Power output P2
160 W
Voltage
230 V
Frequency
50-60 Hz
Power input
1.3 A
Electrical class
I
Speed rotation
2800 rpm
IP rating
IP68
Max. discharge flow Qmax
5.5 m³/h
Max. discharge height Hmax
7.0 m
Max. liquid temperature
40 °C
Max. temperature of the pumped
liquid (5 min)
70 °C
Discharge connection
G 1"
Max. submersion depth
5 m
Max. particle size
1 mm
Type of activation
Manual
Supply cable
10 m
Weight with cable
3.77 kg
2.3 MATERIALS
Pump housing
PP GF
Motor housing
Stainless steel
Motor shaft
Stainless steel
Impeller
PA 6 GF
Seal
Carbon/Ceramic/NBR
Strainer
PE
Screws
Stainless steel
2.4 PUMP CURVE
2.5 LIST OF PARTS SUPPLIED
- integrated non-return valve at the discharge outlet,
- hose connector.
Note: An electronic level controller is available as
an option. See our website.
2.6 DIMENSIONS
3. OPERATION
DANGER
Damaged pump.
Danger of electric shock !
Ö
Prior to commissioning, check the
pump for possible external damages (e.g.
transport damages)
DANGER
Ö
Never carry or suspend the pump by
the power cord.
• Connect a hose to the discharge outlet.
• Place the pump in an initial water level of at least
15 mm to allow priming
.
• Pumping starts when the plug is plugged into
the socket.
• The inlet screen must not be clogged by mud
and/or fibrous media.