12
EN
WARNING
Definition of warning signs:
Indication that a risk of electrical origin exists.
Indication that a risk exists for the machine or its operation.
Directions to be used only by qualified professionals.
Disconnect electrical power before working on the unit!
2
DESCRIPTION
2.1 OPERATING PRINCIPLE
Sanicondens® Mini
contains a pump. The tank of the
SANICONDENS® Mini
has a built-in a float which controls
the operation of the motor. When the condensate enters the tank, the pump starts up.
2.2 TECHNICAL DATA
Type
CD 10
Protection index
IP20
Max. vertical pumping
4.5 m
Sound level
< 45 dBA
Maximum flow rate
380 L/h
Average operating temperature
35°C
Min. pH
2.5
Maximum allowable temperature
80°C
S3 15% (1min30 ON/8min30 OFF)
Level ON/OFF
56 mm / 46 mm
Voltage
220-240 V
Weight of the unit
2 kg
Frequency
50 Hz
Tank volume
2.2 L
Current consumption
0.52 A
Supply cable
1.5 m
Power rating
60 W
Max. power for the connected boiler gas: 50 kW / oil: 30 kW
Electrical class
I
Wall mounting
Yes
2.3 LIST OF PARTS SUPPLIED
See pg. 6.
2.4 DIMENSIONS
See pg. 8
.
2.5 PERFORMANCE CURVES
See pg. 8.
2.6 VERTICAL PUMPING/HORIZONTAL PUMPING
See pg. 8.
1
AREA OF APPLICATION
Sanicondens® Mini
is a pump used to lift condensation water from an air conditioning system, a condensation
boiler, dehumidifiers or from refrigeration units. If necessary, insert a neutralisation device (see your boiler
manufacturer's instructions). The use of a neutraliser is mandatory on oil boilers in order to preserve the
pump.
The pump starts automatically and has a high level of performance, safety and reliability as long as all the
installation and maintenance instructions mentioned in this manual are strictly followed.
All applications other than those described in this manual are prohibited.
3
START UP
3.1 INSTALLATION
Always install the pump:
– horizontally, using a leveling tool,
– as close as possible to the appliance keeping in mind that the condensate has to drain through gravity into the
pump.
To ensure proper ventilation of the motor, the pump must be free of any obstruction.
The pump can be mounted against a wall: see fig.
1
and
2
.
Check that the
Sanicondens® Mini
is leveled: fig.
2
.
3.2 HYDRAULIC CONNECTION
Connecting the inlet
The pump has two inlets Ø28 mm that can be used as required (fig.
3
):
– The left inlet is open.
– The right inlet is protected by a break-off plug. To use the right inlet, first cut out the cut-off plug with a cutter and
remove it.
Drain the condensate water to any of these inlets (fig.
4
). If necessary, use a rubber flexible adapter
A
.