U81
5.1.1. Multiple read reset time
This option can be used in conjunction with
multiple read mode.
• for Laser and CCD readers, it sets the time
that the reader should be pointed away from
the label before it can decode the same label
again
• for Image readers, it sets the number of
frames that the reader should be pointed
away from the label before it can decode the
same label again
Indefinitely means that the next bar code must
always be different, during the time the bar
code reader is triggered.
For the image reader the multiple reset time is
not measured in ms, but in frames. The
duration of each frame is variable, and is
dependent of the captured image. See figure
5.01.
Fig. 5.01. Multiple read reset time
Multiple
read
reset
time
Frames
50 ms
100 ms
200 ms
300 ms
400 ms
500 ms
600 ms
Indefinitely
1
2
3
4
5
6
7
Indefinitely
SET
_ZZ_
50ms
AH
_AH_
100ms
AI
_AI_
200ms
AJ
_AJ_
300ms
AK
_AK_
400ms
AL
_AL_
500ms
AM
_AM_
600ms
AN
_AN_
Indefinitely
AG
_AG_
END
_ZZ_
Содержание KD-3500ZB
Страница 1: ...Configuration guide KD 3500ZB Wireless Area Imaging Scanner...
Страница 2: ...Ui bar code configuration...
Страница 7: ...U4 2 Defaults USB HID...
Страница 71: ...String options 4 U68 7D _7D_ _ 7E _7E_ 7F _7F_ 9T _9T_ 9U _9U_ 9V _9V_ 9W _9W_ SET _ZZ_ END _ZZ_...
Страница 84: ...Read options 5 U80 5 1 Read mode options SET _ZZ_ Single read S0 _S0_ Multiple read S1 _S1_ END _ZZ_...
Страница 97: ...U93 Example C 25 PDF417 Example C 26 MicroPDF417 PDF417 sample bar code MicroPDF417 sample bar code...
Страница 99: ......