![Sewha si 4500 Скачать руководство пользователя страница 47](http://html.mh-extra.com/html/sewha/si-4500/si-4500_operation-manual_1250420047.webp)
DIGITAL WEIGHING INDICATOR
SI 4500
- 56 -
6-9-2. Write Command
※
Each “WRITE” Command’s interval must be guaranteed at least 150ms. If you command another one within
150ms, the indicator will not response. (Under “Check-Sum”, the interval will be 200ms).
P.C ->> SI 4500
Command
SI 4500
Response
STX ID NO. WZER ETX
Make Zero
ACK or NAK
STX ID NO. WTAR ETX
TARE set
ACK or NAK
STX ID NO. WTRS ETX
TARE reset
ACK or NAK
STX ID NO. WPRT ETX
ACK or NAK
STX ID NO. WSPR ETX
Sub-Total Print
ACK or NAK
STX ID NO. WSTC ETX
Sub-Total delete
ACK or NAK
STX ID NO. WBRS ETX
BATCH Stand by
ACK or NAK
STX ID NO. WRUN ETX
Batch Start
ACK or NAK
STX ID NO. WSTB ETX
Batch Stop
ACK or NAK
STX ID NO. WTIM
Time Data(6byte)
ETX
Time Change
ACK or NAK
STX ID NO. WDAT
Date Data
(6byte) ETX
Date Change
ACK or NAK
STX ID NO. WDRI
PRE 1 data
(7/8byte) ETX
PRE 1 value setting
ACK or NAK
STX ID NO. WFRE
Free Fall data
(5byte) ETX
Free Fall value
setting
ACK or NAK
STX ID NO. WFIN
FINAL value
(7/8byte) ETX
FINAL value setting
ACK or NAK
STX ID NO. WSNO
Accumulated Weighing Count
(6byte) ETX
Accumulated Batch
Count setting
ACK or NAK
STX ID NO. WFML
Formula No.
(2byte) ETX
Formula No. setting
ACK or NAK
STX ID NO. WBIN
BIN No.
(2byte) ETX
BIN No. setting
ACK or NAK
STX ID NO. WFTD Formula No., 1th BIN(7/8byte),
BIN(Final data(7/8byte), PRE 1 data (5byte), Free Fall data
(5byte)
)
~No.16BIN Final data(7/8byte), PRE 1 data (5byte), Free
Fall data (5byte)) ETX – Total 282/298byte
Set every Bin data,
Pre 1data. Free fall
data by each formula
ACK or NAK
STX ID NO. WRDY ETX
Commend for reset
Batch
ACK or NAK