DIGITAL WEIGHING INDICATOR
SI 4500
- 26 -
Digital Filter setting
F06
23
AB
A : Frequency Filter setting value (0~3)
(0 : about 200Hz/sec, 3 : about 500Hz/sec)
B : Buffer Filter setting value (1~9)
If “B” set value is fixed, “A” set
value is large, the indicator will
response more sensitive.
Zero /Tare key Operation mode selection
F07
●
0
Activate when “Steady” condition, only
1
Always activated
Zero key Operation Range selection
F08
0
Activated within 2% of Max. Capacity
1
Activated within 5% of Max. Capacity
●
2
Activated within 10% of Max. Capacity
3
Activated within 20% of Max. Capacity
4
Activated within 50% of Max. Capacity
5
Activated within 100% of Max. Capacity
6
Whenever Press “Zero” key (No Limit)
Tare key Operation Range selection
F09
0
Activated within 10% of Max. Capacity
1
Activated within 20% of Max. Capacity
●
2
Activated within 50% of Max. Capacity
3
Activated within 100% of Max. Capacity
Auto TARE Reset selection
F10
●
0
Not use
1
Batch Finish relay output
Auto TARE RESET
key Operation select
F11
0
will not be activated (Can operate with Automatic mode, only)
●
1
will be activated (Can operate with Manual mode)