background image

A 200 receiver

Connectors

Fig. 1:  Front

Fig. 2:  View from above

LED
Light sensor

Touch screen

Connectors

Charging socket

USB port

Microphone socket

ON/OFF key

Activation keys

Содержание AQUAPHON A 200

Страница 1: ...16 09 2019 a 107378 en AQUAPHON A 200 receiver Operating Instructions...

Страница 2: ...A 200 receiver Connectors Fig 1 Front Fig 2 View from above LED Light sensor Touch screen Connectors Charging socket USB port Microphone socket ON OFF key Activation keys...

Страница 3: ...socket Fig 3 Full view Sensor area Fig 4 Handle view from above Fig 5 Adapter Left image Fastening screw with seal Right image Star knob in fastening screw Handle Pipe Adapter Light key LED ON OFF ke...

Страница 4: ...or death A CAUTION Risk of personal injury Could result in injury or pose a risk to health NOTICE Risk of damage to property Note Tips and important information Numbered lists numbers letters are use...

Страница 5: ...2 2 3 Carrying the system 10 2 2 2 4 Playing back noises 10 2 2 2 5 Displaying the measurement values 10 2 2 2 6 Automatic power off 11 2 2 2 7 Main view 11 2 2 3 TS 200 carrying rod 15 2 2 4 Microph...

Страница 6: ...e display 33 3 6 6 Resetting filter settings 33 3 7 Playing back noise repeatedly 34 3 7 1 Opening the Audio Player menu 34 3 7 2 Playing back noise 36 3 7 2 1 Playing back noise with recorded filter...

Страница 7: ...batteries individually using the AC DC adapter or vehicle cable 58 5 2 Handling faulty lithium ion rechargeable batteries 59 5 2 1 Identifying faulty batteries 59 5 2 2 Removing the batteries from the...

Страница 8: ...icrophones for the applications 74 6 5 Operating the system by activation key or sensor area 75 6 6 Accessories 76 6 7 Declaration of conformity 76 6 8 Note about the firmware open source software 77...

Страница 9: ...y be used when performing repairs Changes or modifications to this product may only be carried out with the approval of Hermann Sewerin GmbH Use only Hermann Sewerin GmbH accessories for the product H...

Страница 10: ...instructions apply to the A 200 receiver with firmware version 2 x and higher The manufacturer reserves the right to make changes 1 3 Intended use The AQUAPHON system is intended for professional ind...

Страница 11: ...afety information without fail Risk of personal injury health risk Handle the components carefully and safely both during trans port and when working Proceed with extreme caution in the vicinity of el...

Страница 12: ...hone slips off the contact point The hearing protection function activates when the individu al hearing protection threshold setting is exceeded When the noise from the source of interference ceases h...

Страница 13: ...icrophone System components have already been switched on before the receiver For more detailed information about switching on dependent on switch on mode please refer to section 3 2 on page 21 Startu...

Страница 14: ...be used for Leak detection Pipe location 2 1 3 3 Contact points Each application allows the system to be used on certain contact points The contact point is the area on which a microphone is placed Th...

Страница 15: ...are required for the touch microphone UM 200 universal microphone AC 200 SK4 case The system can be transported and stored in the case The batteries for the components A 200 TS 200 and F8 can be si mu...

Страница 16: ...n Certain areas of the touch screen are touch sensitive Actions are performed by touching these areas buttons All of the buttons have a thick dark grey outline Only your finger or a touch pen should b...

Страница 17: ...receiver has two activation keys Only one of the two keys needs to be pressed to measure LED The LED indicates the operating status Information about what the LED signals mean can be found in section...

Страница 18: ...ack The noises are also recorded Recorded noises can be saved Both recorded and saved noises can be played back 2 2 2 5 Displaying the measurement values Various measurement values are calculated from...

Страница 19: ...in when you want to continue work Switch off backlight The receiver backlight switches off if it is not operated for a specified period of time The receiver remains switched on If and when the automat...

Страница 20: ...us The buttons also display information The information displayed depends on the situation Volume Fig 7 Volume button 1 Current noise level 2 Extreme value 3 Hearing protection threshold 4 Volume The...

Страница 21: ...Fig 8 Audio player button The Audio player menu is opened using the Audio player but ton The following actions can be performed in this menu Play back delete save noise Load and play back noise from...

Страница 22: ...Filter limits limit frequencies of the bandpass Scale for the frequency axis Settings The Settings button displays the following information Application or connected microphone Set type of extreme va...

Страница 23: ...carefully and safely both during trans port and when working Be particularly careful when the touch microphone and probe tip are screwed onto the carrying rod Do not lean on the carrying rod Star kno...

Страница 24: ...Light key The light key on the carrying rod is used to switch the light source for the TM 200 touch microphone on and off Note The light source of the UM 200 universal microphone is switched on and o...

Страница 25: ...umi nate the measuring point Ground micro phone BM 200 Leak detection pin pointing Pipe location Paved Ground micro phone BM 230 Unpaved Paved If ground is very soft use extra spike Orientation of tri...

Страница 26: ...owerful LEDs Do not look directly into the light Never shine the light into the eyes of another person Contact adapter The contact adapter is an accessory with which the microphone can be attached dir...

Страница 27: ...on determines the so called switch on mode If you want the system to start in a specific switch on mode you have to switch on the components in a certain order When the system is switched on a radio c...

Страница 28: ...ion 5 1 on page 57 NOTICE Risk of damage when changing lithium ion bat teries The battery compartments of the components contain parts that could get damaged when the batteries are being replaced Only...

Страница 29: ...ing Microphones can be rinsed under running water Dry the entire microphone connector if necessary Never unscrew the fastening screw all the way out of the thread to minimise the risk of getting dirt...

Страница 30: ...de Starting with the user guide works from the following starting point All components are switched off A microphone has not yet been selected or connected 1 Switch the A 200 receiver on A start scree...

Страница 31: ...hing menu Application leak detection contact point Fitting 4 Follow the instructions in the specified order As soon as a step is complete the corresponding symbols appear in colour Blue The specified...

Страница 32: ...to TS 200 carry ing rod Universal microphone UM 200 to receiver A 200 All components are switched off 1 Switch on carrying rod TS 200 Note Do not touch the sensor area of the carrying rod when switchi...

Страница 33: ...ich microphone can be found in section 6 4 on page 74 The easiest way to tell whether or not a measurement is being taken is by looking at the main view A measurement value is displayed during a measu...

Страница 34: ...protection threshold Protective effect Display colour 1 very high low red 2 high medium orange 3 medium high yellow 4 low very high green A CAUTION Health hazard If the hearing protection threshold is...

Страница 35: ...s the frequencies of the noise This frequen cy analysis is displayed in a graph Fig 15 Frequency graph 1 Frequency axis 2 Lower stopband 3 Lower filter limit 4 Graph of frequency analysis 5 Passband 6...

Страница 36: ...on after switching on the system 3 6 1 3 Purpose of adjustment The filter limits should be set in such a way that any leak noise is accentuated above other noises e g sound interference and is thus cl...

Страница 37: ...bol for the application Fig 16 Settings button in the main view Left image View for default settings shows the application Right image View for adjusted filter settings shows the microphone 3 6 2 Open...

Страница 38: ...Confirm The filter settings will now be applied The re ceiver will switch back to the main view The receiver works with the current filter settings until they are next adjusted 3 6 3 Scanning The scan...

Страница 39: ...nually adjusting filters There are two ways of manually adjusting the filter limits Quick adjustment Exact adjustment 3 6 4 1 Adjusting filter limits quickly A quick adjustment involves resetting both...

Страница 40: ...changes its appearance The filter limit stop range that can be adjusted is displayed in orange 2 Reset the selected filter limit Tap on one of the Move buttons until the desired position is reached 3...

Страница 41: ...he filter limits Scaling is only possible if the upper filter limit is set at or below half of the frequency range Frequency range scaling levels Display scalable if upper filter limit 0 12 kHz 6 kHz...

Страница 42: ...nctions only become available when at least one measurement has been recorded Alternatively you can also load a measurement from the memory The main view is open Tap the Audio player button The Audio...

Страница 43: ...value selection represents measurements by their measurement value numeric value and bar The measurement value selection is divided into the following two areas 7 connected segments for up to 7 record...

Страница 44: ...You can play back a noise in the following ways With recorded filter limits With current filter limits Faster than recorded Note You cannot adjust the volume during playback of a recorded noise 3 7 2...

Страница 45: ...r settings button again The dot on the Filter settings button turns grey again 3 7 2 3 Playing back noise faster If a noise contains a lot of low frequencies it is often hard to hear Audibility usuall...

Страница 46: ...e receiver is switched off SEWERIN recommends Save measurements that contain a lot of information In this way you can create a database to com pare noises The Audio player 1 2 menu is open 1 Tap the m...

Страница 47: ...rmation about this measurement Save the recorded noise again and in doing so add the rele vant additional information Previous additional information is overwritten 3 9 Deleting the recorded measureme...

Страница 48: ...lected The segment is inverted 2 Tap the Open button The Load noise menu appears Fig 23 Load noise menu Top left Filter by date button Centre List of saved measurements 3 Tap the relevant measurement...

Страница 49: ...values that have been saved for the data can be se lected as filter criteria Example Measurements were saved in 2017 and 2019 No measure ments were saved in 2018 The filter criteria available for sele...

Страница 50: ...ppears 3 Tap the Clear button Delete mode is enabled The dot on the Clear button turns red The measurements in the list appear in red 4 Tap the measurement you want to delete in the list The meas urem...

Страница 51: ...the relevant measurement in the measurement value selection 2 Tap Scroll The Audio player 2 2 view appears The availa ble information about the selected measurement is displayed The following informat...

Страница 52: ...asurement the measurement is terminated and not saved Locking 1 Briefly press the ON OFF key The receiver switches to the Switching off menu for 3 seconds 2 Tap Lock display The display switches off i...

Страница 53: ...ly affect the receiver 4 2 Setting actions The settings in the Measurement and Device menus are imple mented as follows Select Enable disable Set value Fig 25 Menu sample diagram Very top Menu item wi...

Страница 54: ...ng is applied immediately without further confirma tion The receiver goes back up a menu level The selected setting is displayed in the higher menu level 4 2 2 Enabling disabling Fig 27 Enabling disab...

Страница 55: ...he value The down key decreases the value 2 Apply the settings by pressing Confirm The receiver goes back up a menu level 4 3 Settings in the Measurement menu Note The settings in the Measurement menu...

Страница 56: ...enu appears 5 Tap Back again to return to the main view 4 3 1 Method The average noise level is displayed There are two ways of cal culating the average noise level The difference between the two meth...

Страница 57: ...activates when the set hearing protection threshold is exceeded Hearing protection can work in two ways The options are Muted The noise is muted so that it can just about be heard above the hearing pr...

Страница 58: ...sor area with your thumb to start the measurement Pressing the sensor area again ends the measurement 4 3 5 Timer A timer can be displayed on the touch screen The timer shows how long a measurement ha...

Страница 59: ...enu This allows you to change the application when the receiver is switched on Typically you might want to change application in the following locating situations When changing from prelocation to pin...

Страница 60: ...ons in the specified order Once all the specified components have been connected the receiver automatically switches to the main view 4 5 Settings in the Device menu Note The settings in the Device me...

Страница 61: ...YYYY Time format 12 h 24 h Language English Service Information Calibration Fig 30 Device menu 3 Adjust the settings as required The Device menu is divided into the four views General Time Date Regio...

Страница 62: ...klight can switch off automatically if it is not operated for a specified period of time The receiver remains switched on Note This function helps save energy It means that the receiver can be used fo...

Страница 63: ...n is disabled a per manent value can be set for the brightness of the touch screen 4 5 5 Time The receiver features an internal clock The set time is displayed in the main view on the Settings button...

Страница 64: ...n the user interface can be displayed in various lan guages There is a range of languages to choose from 4 5 10 Information The relevant current technical information is stored in each re ceiver The f...

Страница 65: ...temperature falls below or exceeds the limit values charging stops until the temperature returns to within the per mitted range There are two ways of charging the components All components at the same...

Страница 66: ...Charging starts automatically After less than 7 5 hours the charging process is complete 5 1 2 Charging batteries individually using the AC DC adapter or vehicle cable The components are connected di...

Страница 67: ...g the housing the components can be damaged mechanically or by electrostatic discharge Lithium ion batteries must only be removed if there is reason able suspicion that they might be faulty Only SEWER...

Страница 68: ...ion 5 2 1 before removing the batteries Avoid electrostatic discharges at all costs e g by using an ESD workstation Fig 32 Back of the A 200 receiver White circles Screws of the battery compartment co...

Страница 69: ...over 3 Disconnect the electrical supply to the faulty battery by pulling off the white plug Never sever the cable 4 Remove the battery 5 Screw the battery compartment cover back on 5 2 3 Removing the...

Страница 70: ...ent is sealed with the battery compartment cover The carrying rod must be switched off 1 Undo the three screws securing the battery compartment cov er on the underside of the handle 2 Remove the batte...

Страница 71: ...be used Never switch the receiver off during the calibration process Always use a touch pen for calibration Work with extreme care The main view is open 1 Tap the Settings button The Settings menu app...

Страница 72: ...WERIN recommends Always remove significant contamina tion immediately Please note the following special points Carrying rod Never use compressed air or a water jet for cleaning Microphones Microphones...

Страница 73: ...102 IC 7994A EZ1300102 Features Display 5 7 TFT display 640 x 480 pixels VGA LED backlight Interface micro USB Memory 90 MB internal Processor RISC 32 bit DSP Operation Touch screen ON OFF key two act...

Страница 74: ...Hz Increment minimum 50 Hz Sampling rate 16 bit 24 kHz Data transmission Transmission frequency 2 408 2 476 GHz 38 channels Radio range 2 m Transmission bandwidth 0 12 kHz Communication SDR Sewerin D...

Страница 75: ...without microphone IP67 with microphone Non permitted operating environments in potentially explosive areas Power supply Power supply lithium ion battery rechargeable 1357 0003 Operating time typical...

Страница 76: ...Operating conditions Operating temperature 20 60 C Storage temperature 25 70 C Protection rating IP65 without TS 200 carrying rod IP67 with TS 200 carrying rod Non permitted operating environments in...

Страница 77: ...each 15 cd Operating conditions Operating temperature 20 80 C Storage temperature 25 80 C Protection rating IP68 Non permitted operating environments in aggressive media in potentially explosive areas...

Страница 78: ...d etc Symbol greyed out Function disabled system component not connected etc Symbol Significance Confirm Cancel Back Scroll A 200 receiver TS 200 carrying rod Microphone No microphone connected Microp...

Страница 79: ...on Paved Unpaved Fitting Universal Measurement settings Application settings Device settings Timer forwards Timer backwards countdown Scan Symbol Significance Reset Speed Filter settings Open Filter b...

Страница 80: ...switched on Flashing 0 1 s on 0 9 s off ongoing Battery charging Double flash 0 1 s on 0 1 s off 0 1 s on 0 7 s off ongoing Battery is fully charged Red Light per manently on A 200 switched on Underv...

Страница 81: ...1 s on 0 9 s off ongoing Battery charging Double flash 0 1 s on 0 1 s off 0 1 s on 0 7 s off ongoing Battery is fully charged Red Light per manently on TS 200 switched on Radio connection to A 200 est...

Страница 82: ...erview of which microphones are suitable for which applications and contact points Application Contact point Microphone Leak detection Paved BM 200 Unpaved Paved BM 230 Unpaved Paved Fitting Universal...

Страница 83: ...iew of which controls are suitable depending on the microphone Component Operated using on Operating mode Touch Switch BM 200 BM 230 Activation key A 200 o Sensor area TS 200 o o TM 200 Activation key...

Страница 84: ...rrying system 3209 0012 Lap belt carrying system EA20 Z1000 Triangle 200 carrying strap 3209 0022 Hand loop EA 200 3209 0017 AC DC adapter L LD26 10000 Vehicle cable L 12 V ZL05 10200 Other accessorie...

Страница 85: ...rt of the services due The source code is available on request at cost price by emailing info sewerin com The full licence terms can be found online www sewerin com 6 9 Advice on disposal The European...

Страница 86: ...ng screw 15 Faulty lithium ion rechargeable battery 59 Filter button 13 menu 29 Filter limits 27 exact adjustment 31 quick adjustment 31 Filter settings 27 adjusting 27 adjustment options 28 applying...

Страница 87: ...r supply 20 R Receiver 7 carrying the system 10 connectors 9 ports 9 product variants 7 Rechargeable battery see Lithium ion rechargeable battery S Scan 30 Scan frequency range 30 SDR 4 Sensor area 15...

Страница 88: ...ower Avenida Sur del Aeropuerto de Barajas 28 Of 2 1 y 2 2 28042 Madrid Espa a Tel 34 91 74807 57 Fax 34 91 74807 58 www sewerin es info sewerin es Sewerin Portugal Lda Rua do Senhor dos Milagres 16 2...

Отзывы: