![SEW DRC.-...-DAC Скачать руководство пользователя страница 64](http://html1.mh-extra.com/html/sew/drc-dac/drc-dac_operating-instructions-manual_1250005064.webp)
64
Operating Instructions – Electronic Motor DRC.-..-DAC
5
Assignment of optional plug connectors
Electrical Installation
5.9.3
X5502: STO – IN
The following table informs about this connection:
WARNING
No safe disconnection of the DRC drive unit.
Severe or fatal injuries.
• Do not use the 24 V output (pins 1 and 3) for safety-related applications with DRC
drive units.
• You may only jumper the STO input with 24 V when the DRC drive unit need not
fulfill any safety function.
Function
Input for safe torque off (STO)
Connection type
M12, 5-pole, female, A-coded
Wiring diagram
2264816267
Assignment
No.
Name
Function
1
+24V_O
DC 24 V output
2
STO
−
Input STO –
3
0V24_O
0V24 reference potential
4
STO +
Input STO +
5
res.
Reserved
1
4
3
2
5