MOVITRAC
®
31.. PROFIBUS Fieldbus Interface
29
The PROFIBUS-DP
Interface
3
01185AEN
Fig. 33: Sending output data to the inverter and saving them temporarily
When a new Sync command is issued, all inverters simultaneously update their active setpoints
with the value temporarily stored before (Fig. 34). In other words, the active setpoints are not
updated until the new Sync command has been received. The inverters quit Sync mode when the
Unsync control command is issued.
01186AEN
Fig. 34: Simultaneous activation of the new setpoints with the Sync command
1500 min
-1
0 min
-1
PROFIBUS-DP
1500 min
-1
1500 min
-1
0 min
-1
0 min
-1
1) Setpoint to inverter 1
2) Setpoint to inverter 2
3) Setpoint to inverter 3
Buffer storage
Active setpoint
1500 min
-1
1500 min
-1
PROFIBUS-DP
1500 min
-1
1500 min
-1
1500 min
-1
1500 min
-1
Sync
Buffer storage
Active setpoint