9
Data exchange with higher-level controller
F-process output data
Manual – MOVISAFE
®
CSB51A Safety Option
33
9.3
F-process output data
Byte Bit Name
Value Description
0
0
STO1
0
Activate STO.
1
Deactivate STO.
1
Reserve
2
Reserve
3
Reserve
4
Reserve
5
Reserve
6
Reserve
7
Fault ac-
knowledg-
ment
0
No acknowledgment.
1
Fault acknowledgment (0 → 1 edge).
1
0
Reserve
1
Reserve
2
Reserve
3
Reserve
4
Reserve
5
Reserve
6
Reserve
7
Reserve
2
0
Reserve
1
Reserve
2
SSX1
0
Activate SSx1.
1
Deactivate SSx1.
3
SSX2
0
Activate SSx2.
1
Deactivate SSx2.
4
Reserve
5
Reserve
6
Reserve
7
Reserve
9.3.1
Substitute values
In the F-controller, all bits described as "Reserve" must be set to "0".