3
Electrical installation
Electrical connections
Revision – MOVIPRO
®
PHE10A-..-3..A-00..
25
3.2.11
X4111: CAN bus – external
INFORMATION
If there is no station connected here, you must terminate the bus with a 120 Ω res-
istor.
Function
CAN bus for external components
Connection type
M12, 5-pole, female, A-coded
Wiring diagram
1
4
3
2
5
No.
Name
Function
1
CAN_SHLD
Shield/equipotential bonding
2
+24V
DC 24 V output
3
GND
Reference potential
4
CAN_H
CAN data line (high)
5
CAN_L
CAN data line (low)
Connection cables
Cable
Length/installation
type
Component
Length 5 m:
Part number: 13286331
Length 10 m:
Part number: 13286358
Length 15 m:
Part number: 13286366
Cable design: ((1X2X0.2)+(1X2X0.32)+1X0.32)
M12, male, A‑coded ↔ M12, female, A‑coded
Set length
–
23541253/EN – 05/2017