8
Addendum to the Operating Instructions – MOVIMOT® MM..D Retrofit Set AC Motors DRS/DRE/DRP
2
Assembly
Mechanical Installation
12.
Only for brakemotors:
Connect the connection cables of the
BE.. brake as follows:
• Red to terminal X1:13
• White to terminal X1:14
• Blue to terminal X1:15
(Tightening torque of the terminals
0.8 – 1.1 Nm / 7– 10 lb.in)
13.
Only for motors without a brake:
Install the BW.. braking resistor in the
terminal box using 2 screws.
(Tightening torque 1.4 – 1.6 Nm /
12 – 14 lb.in)
Connect the BW.. braking resistor to
terminals X1:13 and X1:15.
(Tightening torque of the terminals
0.8 – 1.1 Nm / 7 – 10 lb.in)
Terminal X1:14 must not be assigned.
14.Place the MOVIMOT
®
inverter onto the
terminal box and secure it using 4
screws.
(Tightening torque 3.0 Nm / 27 lb.in)
After successful retrofitting, startup the MOVIMOT
®
drive according to the "MOVIMOT
®
MM..D with AC Motors DRS/DRE/DRP" operating instructions.
BE
X1: 13
X1: 14
X1: 15
RD
WH
BL
9007200043226123
X1: 13
X1: 14
X1: 15
BW1 / BW2
9007200043479691
2602175499