MOVIDRIVE
®
PROFIBUS DFP11A
47
Technical Data
6
6
Technical Data
SEW No. for Profibus Option PCB:
822 724 1
Profibus protocol options:
• PROFIBUS-FMS to DIN 19245 Part 2
• PROFIBUS-DP to DIN E 19245 Part 3
• Mixed mode PROFIBUS-FMS/DP (Combislave)
Auto-baud detect for:
• 9.6 kBaud
• 19.2 kBaud
• 93.75 kBaud
• 187.5 kBaud
• 500 kBaud
• 1500 kBaud
Connection system:
• 9-pin type D connectors
• Pin assignment to DIN 19245 Part 1 / EN 50170
Bus termination:
• Connectable for cable type A (up to 1500 kBaud) to DIN E 19245 Part 3 / EN 50170
Station address:
• 0-125 settable via DIP switch
Default bus parameter:
• Min TSDR for FMS/DP and DP mode selectable via DIP switch
Name of GSD file:
• SEW_6000.GSD
DP Ident Number:
• 6000hex = 24576dec
DP configurations for DDLM_Chk_Cfg:
• F0 hex = 1 process data word (1 I/O word)
• F1hex = 2 process data words (2 I/O words)
• F2hex = 3 process data words (3 I/O words)
• F3hex, F0hex = parameter c 1 process data word (5 I/O words)
• F3hex, F1hex = parameter c 2 process data words (6 I/O words)
• F3hex, F2hex = parameter c 3 process data words (7 I/O words)
Commissioning tools:
• MX_SHELL software, version V1.00 and higher
• DBG11 control keypad