4
Mechanical installation
Coupling of AM adapters
Assembly and Operating Instructions – Gear unit series R..7, F..7, K..7, K..9, S..7, SPIROPLAN
®
W
64
Permitted loads for gear unit series SPIROPLAN
®
W37 – W47
Adapter type
F
R
1)
in N
IEC
NEMA
x
1)
in mm
IEC adapter
NEMA adapter
AM63/71
AM56
115
140
120
AM80/90
AM143/145
151
270
255
1) As the center of gravity distance x increases, the maximum permitted weight of
the attached motor
R_max
must be reduced linearly. If this center of gravity distance
x is reduced, the maximum permitted weight F
R_max
cannot be increased.
4.9.3
AM adapter with AM../RS backstop
Check the direction of rotation of the drive prior to assembly or startup. In case of a
wrong direction of rotation, contact SEW
‑
EURODRIVE.
The backstop is maintenance-free in operation. Backstops have a minimum lift-off
speed depending on the size (see following table).
NOTICE
If the speed is below the minimum lift-off speed of the drive, the backstop is subject
to wear and heats up.
Possible damage to property.
• In nominal operation the lift-off speed of the drive must not drop below the speci-
fied minimum.
• During startup or braking, the lift-off speed of the drive may drop below the mini-
mum levels.
Type
Maximal locking torque of the back-
stop in Nm
Minimum lift-off speed
in 1/min
AM80/90/RS,
AM143/145/RS
65
820
AM100/112/RS,
AM182/184/RS
425
620
AM132/RS,
AM213/215/RS
850
530
AM160/180/RS,
AM254/286/RS
1450
480
AM200/225/RS,
AM324-365/RS
1950
450
AM250/280/RS
1950
450