9
Malfunctions
Lubricants
Assembly and Operating Instructions – Gear unit series R..7, F..7, K..7, K..9, S..7, SPIROPLAN
®
W
157
9
Malfunctions
WARNING
Risk of crushing if the drive starts up unintentionally.
Severe or fatal injuries.
• De-energize the motor before you start working on the unit.
• Secure the motor against unintended power-up.
CAUTION
Risk of burns due to hot gear unit and hot gear unit oil.
Severe injuries.
• Let the gear unit cool down before you start working on it.
• Carefully remove the oil level plug and the oil drain plug.
NOTICE
Damage to gear unit due to improper operation.
Damage to the gear unit/gearmotor.
• Repair works at SEW
‑
EURODRIVE gear units may only be performed by quali-
fied personnel. I the context of this documentation, qualified personnel are per-
sons who are familiar with the "Technical regulations on operating safety"
(TRBS).
• Drive and motor may only be disconnected by qualified personnel.
• Contact SEW
‑
EURODRIVE.
21932786/EN – 05/2015