DFS/DFY Synchronous Motors
13
Electrical Connection
3
• Twisted pair cable with shield connected at both ends over as large an area as possible.
• Clip on with strain relief clamps (over as large an area as possible).
• The socket contacts are implemented as crimp contacts. Use only suitable crimping tools for
crimping.
• Strip insulation off lead wires over length A (see Appendix, Table 1). Pull shrink sleeve over
connections.
• Remove incorrectly mounted socket contacts with suitable removal tools only.
• Secure plug connector with coupling ring.
Pin
Connection
Core
10
GND
supply
contact separation from housing
BN
7
V
S
+ 13 ... 15 ... 24 V
DC
, polarized
WH
14
Data+
data output, serial
high = “1” (positive logic)
BK
17
Data–
high = “0”
VT
8
Pulse+
Takt, Stromschleife
7 mA in direction pulse+ = “1”
PK
9
Pulse–
7 mA in direction pulse– = “0”
GY