12
The quick-freeze compartment is marked with the symbol
(on the inside of the door).
Before using for the
fi
rst time
∙
Remove any packaging materials including the adhesive
strips as well as any protective plastic foils found.
∙
Before it is connected to the mains, the unit must be
thoroughly checked for transport damage, including its
power cord.
∙
Clean the unit as described in the section
De-frosting and
cleaning
.
∙
Once the unit has been positioned, wait for about 30
minutes before it is connected to the mains.
∙
If the unit has been tilted more than 30° during transport,
allow it to stand upright for at least 4 hours before it is
connected to the mains.
∙
When the unit is
fi
rst switched on, a slight ‘new’ smell may
be noticed. However, this will disappear once the cooling
process has begun.
Installation
∙
The appliance should be set up in a well-ventilated, dry
room.
∙
It should be operated in conditions where the relative
humidity is no more than 70 %.
∙
The product data sheet contains details of the ambient
temperature range suitable for this appliance.
∙
Do not use the appliance outdoors. Ensure that the plug is
accessible and can be removed from the wall socket at any
time.
∙
Do not expose the appliance to direct sunlight, and do not
position it next to any heat sources (radiators, cookers etc).
If this cannot be avoided, however, suitable insulation must be
in installed between the heat source and the unit.
∙
The unit must not be installed inside a cupboard; when
positioning the unit, also ensure that it is not placed directly
underneath a shelf or any other similar object.
∙
Ensure that there is suf
fi
cient space in front for the door to
open to 160°.
∙
In the case of uneven
fl
oors, the adjustable feet at the front
can be used to compensate and ensure optimum stability.
Ventilation
Ensure that there is enough space around the unit so that the air
circulation round and behind it is not obstructed. (Rear and sides 5
cm, top 10 cm.)
Reversible door
The design provides for the door to be reversed, i.e. for right-
hinged (default installation) to become left-hinged.
Warning:
Always disconnect the unit from the mains before
any maintenance or repair work is carried out.
1. Remove the four screw covers (11) and the screws (10).
2. Remove the top panel (9), and the cover plate (8) from the
front.
3. Remove the two screws (6) securing the upper hinge plate
(5) on the right-hand side.
4. Carefully lift up the door and place it on a suitable surface
to protect it from scratches.
5. Take off the white plug (7) and re-position it in the
corresponding hole on the right-hand side, pushing it
fi
rmly
down.
6. Remove the two screws (1) securing the lower hinge plate
(2) on the right-hand side.
7. Take out the adjustable foot (4) and re-position it on the
right-hand side.
8. Mount the lower hinge plate (2) using both screws (1) in
its new position on the left. Ensure that the plate is aligned
parallel to the side edge of the unit. (Do not fully tighten
the screws yet.)
9. Replace the door in its new position. Ensure that the
hinge pin of the lower hinge plate is inserted into the guide
bushing (hole) in the door.
10. Mount the upper hinge plate (5) using both screws (6) in
its new position on the left. Ensure that the hinge pin is
inserted into the guide bushing (hole) in the door. (Do not
fully tighten the screws yet.)
11. Close the door and ensure that it is properly aligned
before fully tightening the screws of the upper and lower
hinge plates.
12. Fit the top panel (9) on the unit and – with the door open
– replace the cover plate (8) into the opening on the right-
hand side of the front.
13. Replace the screws (10) and screw covers (11) on the top
panel (9).
14. Put the unit back in its intended position and wait for about
two hours before connecting it to the mains.
Содержание KS 9890 - CONGELATEUR TABLE TOP
Страница 68: ...68 R600a GR...
Страница 69: ...69 C5 H10 R600a 8 2...
Страница 70: ...70 1 2 3 4 5 30 30 4 70 160 5 cm 10 cm 1 11 10 2 9 8 3 6 5 4 5 7 6 1 2 7 4...
Страница 71: ...71 8 2 1 9 10 5 6 11 12 9 8 13 10 11 9 14 Min Normal Max 18 C 3 3 5 24...
Страница 72: ...72 10 5 3 5 24...
Страница 73: ...73 30 30 30 4 MIN...
Страница 74: ...74 KS KS 9890 A kWh 166 65 15 24 3 5 N ST C 16 38 C 43 dB a x x mm 847 x 494 x 494 27...
Страница 75: ...75 R600a RU...
Страница 76: ...76 C5 H10 R600a 8 2...
Страница 77: ...77 1 2 3 4 5 30 30 4 70 160 5 10...
Страница 78: ...78 1 11 10 2 9 8 3 6 5 4 5 7 6 1 2 7 4 8 2 1 9 10 5 6 11 12 9 8 13 10 11 9 14 Min Normal Max 18 C 3...
Страница 79: ...79 3 5 24 10 5 3 5 24...
Страница 80: ...80 30 30 30 4 MIN...
Страница 81: ...81 Severin 2 a x KS KS 9890 A 166 65 frost free 15 3 5 N ST C 16 38 C 43 dB a x x 847 x 494 x 494 27...