6. Trouble shooting
Problem
Possible cause
Solution
Engine does not work
No fuel
Refill fuel
tank cap vent valve
“CLOSED”
tank cap vent valve pos.
“OPEN”
Fuel tap “OFF”
Fuel tap pos. “ON”
Spark plug dirty or loose
clean spark plug, check
electrode gap, remove fuel
excess
Engine switch “OFF”
Engine switch “ON”
oil warning LED (red)
glows
Check oil level, refill oil
Generator stops during
operation
No fuel
Refill fuel
too low oil level
Check oil level, refill oil
tank cap vent valve
“CLOSED”
tank cap vent valve pos.
“OPEN”
ac socket without function
overload LED (red) glows.
Generator is overstrained
turn off generator. check
connection power of
consumer and if necessary
reduce. Restart generator
Dc socket without function charging current too high.
Dc fuse tripped
Disconnect the battery and
turn on Dc fuse again.
If no functionality can be achieved even with these measures, you should find an authorised service station.