Setech ST-EG100-E Скачать руководство пользователя страница 21

ST-EG100-E Installation and User Guide Configuration 

 

ChangeIP www.changeip.com 

Any DDNS provider that adheres to the standard protocol used by these DDNS servers would 
work.  

Select a DDNS provider and visit their website to sign up for a free account. The free accounts 
they offer are basic, but sufficient for accessing the ST-EG100-E from the Internet. For 
additional fees, each provider has “extras” such as letting you select a fully custom URL, email 
services, etc. The free service allows you to select a URL in one of their “sub-domains.” For 
example, DynDNS has nearly one hundred sub-domains to choose from, one being 
“dyndns.org.” You can prepend any name to the front of it (so long as it’s not already taken) 
such as “MyM1,” giving you the URL “MyM1.dyndns.org.” Please be sure to read and adhere to 
the provider’s policies. Because they provide the service for free, they must institute rules to 
prevent abuse of their service. 

After setting up the account (it may take a day or two for it to begin working), enter the setup 
information for that account on the Dynamic DNS tab of the M1XEP Setup window in ElkRP2. 

1.

 

In the first box, enter the DDNS provider’s update URL. The ST-EG100-E connects to this 
URL to update the provider whenever the IP address changes. 

2.

 

Below that, enter the username and password you chose when setting up the account on the 
provider’s website. The ST-EG100-E needs this information to log into the provider’s site to 
perform the updates. 

3.

 

In the Host Name box, enter the custom URL you selected (ie. mym1.dyndns.org). 

4.

 

The ST-EG100-E can send you or anyone else an email message whenever an error occurs 
during an update. This is to notify you that your custom URL will not work until the update 
is successful. To enable this feature, enter the email address in the next box. You must also 
fill in the necessary information on the Email tab (refer to Email Notification Section 3.4.2). 

5.

 

In addition to notifying you of update errors, you may also want to know when a successful 
update occurs. Check the last box to enable this. 

6.

 

SEND the setup to the control, then activate the 

Test

 button to test that the ST-EG100-E can 

contact the DDNS provider. The test does not perform an actual update, as the provider 
would consider that an abuse of their service. Instead, it simply checks that it can connect to 
the provider. 

How the ST-EG100-E DDNS updates work: 

Every few minutes, the ST-EG100-E “checks in” with the DDNS provider to find its public IP 
address. When the ST-EG100-E detects that the public IP address has changed, it logs in to the 
provider’s website and sends a message containing its new IP address. Most providers will delete 
a free account if it is not updated every month or two. To prevent this, the ST-EG100-E will 
“force” an update every thirty days even if its public IP address hasn’t changed. If you enabled 
email notification of updates, you will be notified when this occurs. Most providers consider it 

SETECH Security & Automation

  

Revision 

96-300001  

Page 21 of 44 

Содержание ST-EG100-E

Страница 1: ...Copyright 2013 SETECH Security Automation ST EG100 E Ethernet Gateway Installation and User Guide ...

Страница 2: ...corporates these changes into new editions of this document SETECH may make improvements and or changes to the product s and or the program s described in this document at any time Revision History Revision Revision Date Change Description A 20 Nov 2013 Original version ELK ELK M1 M1toGO ElkRP2 are registered trademarks of Elk Products iOS is a registered trademark of Apple Inc Android is a regist...

Страница 3: ...Email Notification 16 3 4 2 1 Enhanced Email Notification EEN 17 Zone Status Report 20 Zone Alarm Report 20 Area Arming Status Report 20 3 4 3 Dynamic DNS Setup 20 3 4 4 Time Server 22 3 4 5 Advanced Filtering Content of Zone Status Reports 22 3 5 ROUTER SETUP NOTES 23 3 5 1 Port Forwarding 23 3 5 2 Other Ports Used by the Elk M1XEP 24 CHAPTER 4 VIRTUAL KEYPAD 25 4 1 VIRTUAL KEYPAD ACCESS 25 4 2 W...

Страница 4: ...on Omnistat2 EEN provides embedded dynamic reports Zone Status Zone Alarm and Area Status to multiple email recipients using standard and encrypted SMTP email services 1 2 Elk M1XEP Compatibility Configuration and firmware updated through ElkRP2 M1toGO eKeypad myKeypad and MobiLinc Secure encryption password authentication Dynamic DNS DDNS support DHCP protocol configuration SNTP Time Server Suppo...

Страница 5: ...mited by ElkRP2 Email Address Length 48 Character Maximum through ElkRP2 Unlimited through Virtual Keypad Email Message Length 255 Character Maximum Not including embedded reports 1 4 Controls and Indicators Table 1 RJ 45 Network Jack LEDs LED Indicators Description Normal State Orange Processor Power Indicator On Solid Green Network Traffic Indicator On Blinking During a reboot the green light wi...

Страница 6: ...main name to be assigned to a varying IP address This makes it possible for other sites on the Internet to establish connections to the machine without needing to track the IP address themselves A common use is for running server software on a computer that has a dynamic IP address e g a dial up connection where a new address is assigned at each connection or a DSL service where the address is cha...

Страница 7: ...ally identify the manufacturer The remaining digits uniquely identify the specific interface on that individual device Also known as a physical address Example 00 40 9D 25 6E C0 NTP Network Time Protocol The protocol for requesting and receiving the current time from a time server Port The identifier used by Internet transport protocols to distinguish among multiple simultaneous connections to a s...

Страница 8: ... 1 96 300001 Page 8 of 44 are assigned a unique URL Also known as an Internet address or web address Example http www setechautomation com WAN Wide Area Network A computer network covering a wide geographical area involving vast array of computers The best example of a WAN is the Internet ...

Страница 9: ...For locating the ST EG100 E further from the panel an optional serial cable may be ordered directly from SETECH Mounting Hole Typical for 4 RJ45 Network Jack DC Power Connector DB9 Serial Male Connector Figure 1 SETECH ST EG100 E Ethernet Gateway Board 3 Connect the female end of the supplied DB9M serial ribbon cable to the male DB9 connector on the ST EG100 E and connect the other end of the ribb...

Страница 10: ... terminal on the M1 Control board Reapply power to the M1 Control board If using the optional ST 12VPS power adapter plug its AC power cord into an AC power receptacle 7 The ST EG100 E powers up and attempts to link with the Ethernet network 8 Enroll the ST EG100 E into the M1 Control using the keypad as follows a Access the Installation Programming Menu 9 b Select Bus Module Enrollment Menu 01 an...

Страница 11: ...d the Virtual Keypad to have and display the information Using the Keypad Installer Programming or the ElkRP2 software access the Globals Menu Menu 07 and program yes for options 35 36 37 38 39 and 40 Verify that Option 34 is set to 115 200 3 3 Initial Network Setup A DHCP enabled router does not require any additional configuration to allow the ST EG100 E to connect inside the local network For c...

Страница 12: ...ured static IP address or if no static address was previously configured the factory default IP address of 192 168 0 251 5 Highlight left click the ST EG100 E device to configure and activate the Use Selected button to copy the IP address and Port settings into the corresponding System URL IP and Port fields in the ElkRP2 Account Details panel The system closes the Find M1XEPs window You should no...

Страница 13: ...etwork administrator or Internet service provider and enter the following information as shown in Figure 4 See below for example IP Address e g 192 168 14 76 Subnet Mask e g 255 255 255 0 Default Gateway e g 192 168 14 70 NOTE If you switch back to a DHCP server assigning a dynamic IP address the system reverts to the last programmed static IP address whenever it fails after 1 minute to obtain a d...

Страница 14: ...01 In order to remotely access the M1 Control from the Internet your router must be configured to map this port port forwarded Refer to documentation for your router to configure port forwarding Figure 4 ElkRP2 TCP IP Settings 15 Activate the Send button to save network configuration changes to the ST EG100 E and the system displays the M1XEP Reboot Required dialog box see Figure 5 Figure 5 Reboot...

Страница 15: ...pply the changes Reboot takes up to 2 minutes to complete and a connection can not be re established with the ST EG100 E until reboot is complete If the network address configuration has been changed it will be necessary to update the ElkRP2 configuration as described previously 19 Select Save Account from the File pull down menu located at the top of the ElkRP2 window to save all changes to the E...

Страница 16: ... Setup Email Notification To be notified via email for defined events e g system disarmed by a specific user setup email notification as follows 1 Connect to the ST EG100 E from ElkRP2 2 Activate the Email tab in the M1XEP Setup window 3 Enter the outgoing SMTP server s URL or IP address in the Server URL IP Address field e g smtp gmail com This field supports a maximum entry of 48 characters 4 In...

Страница 17: ... the email addresses for both mom and dad mom office job dad work job ensures that both parents are notified when Mike arrives home 10 Activate the Send button to save Email configuration changes to the ST EG100 E Refer to steps 15 through 19 of Section 3 3 for instructions on sending changes to ST EG100 E and saving to local ElkRP2 database 11 To send a test email activate the Test button Please ...

Страница 18: ...eyword Alternate Keyword Description EMAIL_ID EI Insert the email message number for this email Example See EMAIL_SUBJECT for example Keyword Alternate Keyword Description ZONE_STATUS ZS Insert a zone status report in the email message Refer to Section 3 4 5 for advanced filtering of reports Keyword Alternate Keyword Description ZONE_ALARM ZA Insert a zone alarm report in the email message Keyword...

Страница 19: ...ST EG100 E with Email Address for Message 1 of test home com The FROM email address defined in M1XEP Setup is EG100E home com Message Definition ES DEVICE_NAME Custom Subject Test for Email EI A test email for multiple recipients and custom subject with embedded reports for DEVICE_NAME EMAIL_ALSO test2 home com ZS ZA AAS SETECH Security Automation Revision 1 96 300001 Page 19 of 44 ...

Страница 20: ...net you need to know its Public IP Address The Internet service provider may change that IP address from time to time Because IP addresses change and are difficult to remember you can sign up for a free or low cost service known as Dynamic DNS This service allows you to select a semi custom URL and register it to your IP address When your IP address changes the DDNS service will update your URL to...

Страница 21: ...rmation to log into the provider s site to perform the updates 3 In the Host Name box enter the custom URL you selected ie mym1 dyndns org 4 The ST EG100 E can send you or anyone else an email message whenever an error occurs during an update This is to notify you that your custom URL will not work until the update is successful To enable this feature enter the email address in the next box You mu...

Страница 22: ...then state or province Don t mistake a country abbreviation for a state abbreviation 5 Enter the URL or IP address of the server in the first box Select a time of day for the updates Updates will be performed daily at this time Select an off the hour time such as 2 18 AM rather than 2 00 AM This will reduce the likelihood of a Rule being triggered twice If the M1 EZ8 is programmed with a Rule that...

Страница 23: ... Example filter including zone status filtering 1 208 VIOLATED report only violated zones in the range 1 through 208 1 4 6 BYPASSED VIOLATED report bypassed or violated for zones 1 4 5 and 6 Syntax for each given example ZS 1 4 7 12 or ZONE_STATUS 1 4 7 12 ZS 1 208 VIOLATED or ZONE_STATUS 1 208 VIOLATED ZS 1 4 6 BYPASSED VIOLATED or ZONE_STATUS 1 4 6 BYPASSED VIOLATED 3 5 Router Setup Notes 3 5 1 ...

Страница 24: ...f ElkRP2 will connect through FTP or TCP Internet WAN to download firmware updates to the Elk M1XEP FTP or TCP 80 8080 Web Browser Route outside to connect with web browser TCP through Internet WAN TCP 443 8443 Web Browser encrypted Route outside to connect with web browser TCP through Internet WAN TCP 3 5 2 Other Ports Used by the Elk M1XEP The following table contains additional ports used by th...

Страница 25: ...ogin authentication is performed by the ST EG100 E and acts as a firewall preventing unauthorized access to the Elk M1 Control Usernames and Passwords are configured on the Password tab of the M1XEP setup screen of the ElkRP2 By checking the Save Login Information box following the initial entry of a valid Username and Password this screen will be bypassed Figure 8 User Authentication 4 3 Security...

Страница 26: ...rface displays overall system status and provides many of the operations that are available from a physical keypad Selections are available for choosing the Area and Keypad configured on the security panel The area selection allows selecting the area to display and control Areas restrictions are based on the user code entered to initially access the keypad interface By default information for the ...

Страница 27: ...lays solid green when the system is ready to be armed If any zone is not in a ready state this indicator will be shown is a disabled state grey Auxiliary Buttons Refresh Forces a refresh of all system settings This can be used to repaint the screen in the event of a communications failure Status The Status button displays all zones defined in the currently selected area by name along with their st...

Страница 28: ...respective zone and clicking on OK will toggle its bypass state o Ignore Zone is currently being monitored Activating checkbox will place the zone in bypass mode o Monitor Zone is currently in bypass mode Activating checkbox will place the zone in un bypass mode Instant Allows the user to set the current arming mode to instant Instant mode forces an immediate alarm if an entry zone is violated Thi...

Страница 29: ...AY mode Subsequent clicks during the arming process will place the system in the next configured stay mode 4 4 2 Lighting Page The lighting interface shows the current state of the defined lighting devices that have their Show state set within ElkRP2 and allows setting of the lighting state The current lighting state is shown by an ON OFF indicator that illuminates green when the light is on and g...

Страница 30: ...unt of time The maximum supported time is 2 hours 46 minutes and 39 seconds 9999 seconds Set Time Button Requests the checked components be turned on off for the specified amount of time 4 4 3 Climate Page The climate display shows the current state of thermostats interfaced to the system and allows control of the thermostat settings By default the first defined thermostat is displayed An option m...

Страница 31: ...m Temperature Ambient temperature of the currently selected thermostat Humidity Relative humidity of the currently selected thermostat Omnistat2 only Outside Remote Probe temperature of the currently selected thermostat Omnistat2 only Heat Cool Setpoint Temperature at which the associated system will be activated Mode Selects the thermostat control mode Off Disables climate control Heat Prevents t...

Страница 32: ...s On Fan runs continuously Cycle Fan is cycled on and off based on the configuration of the thermostat to circulate the air Omnistat2 only Hold Controls program schedule temperature settings Off Thermostat responds to program schedule temperature setting changes On Thermostat ignores program schedule temperature setting changes Vacation Thermostat ignores program schedule temperature setting chang...

Страница 33: ...bes invalid values keypads not equipped with temperature probes will be displayed as double dashes 4 4 4 Tasks Page The tasks display presents a list of the named tasks from the system with the Show option enabled A task can be activated by pressing the button indicator beside the task The indicator will illuminate to indicate the task request has been made The indicator extinguishes when the syst...

Страница 34: ...To display outputs 64 to 208 the Show Output 32 check box needs to be selected within ElkRP2 The outputs are displayed in a list by output number with their assigned name and the current state of the output Selecting an output from list will highlight that output and update the displayed output state The current state is shown by a green indicator for an output that is on or a gray indicator for a...

Страница 35: ...ected the label next to the Status Button will be blank Clicking on the Status Button causes the output state to be toggled Turn On Requests the selected output be turned on for the specified amount of time Show Outputs 64 Controls whether or not the upper group of un named outputs are shown SETECH Security Automation Revision 1 96 300001 Page 35 of 44 ...

Страница 36: ...ple email recipients Group Name An alias used to expand the Email Address column in the Elk RP2 M1EXP Setup dialog If a matching label is found in the email configuration table the corresponding message will be sent to the associated addresses Recipients Email mailing list Multiple email addresses are separated by a Add Opens the Add Group dialog window and recipients defined one per line SETECH S...

Страница 37: ... the Confirm Delete dialog window for the currently selected entry Edit Opens the Edit Group dialog window for the currently selected entry Save Stores the current alias table on the Ethernet module server SETECH Security Automation Revision 1 96 300001 Page 37 of 44 ...

Страница 38: ...og table maximum of 512 log entries Date Date time the system event was recorded Area Area in which the event occurred Event Brief description of the system event followed by the event and extended data codes in brackets refer to ELK documentation for more detailed information SETECH Security Automation Revision 1 96 300001 Page 38 of 44 ...

Страница 39: ...nse key has been installed on the Ethernet module web server the server will generate a 15 day temporary license If the license is allowed to expire the virtual keypad will no longer be available and the user will be presented the following when attempting a connection SETECH Security Automation Revision 1 96 300001 Page 39 of 44 ...

Страница 40: ...fic for your Ethernet Gateway Note this link will allow the download of an encrypted file compatible only with the hardware originally purchased 3 Using the provided link download and save the firmware installation package to your local drive and uncompress the contents of the installation package The uncompressed installation package includes both the firmware installation application i e SETECH ...

Страница 41: ... entry box in the SETECH Updater window 8 Activate the Update button to start the update process see Figure 12 CAUTION The update process takes several minutes to complete Do not interrupt or remove power from the Ethernet board until the update process is complete An interruption of the update process may result in the Ethernet board becoming non responsive If the update process is interrupted re...

Страница 42: ...operly Check the serial baud rate in the M1 This setting can be accessed through the keypad by entering Menu 9 Installation Programming or Sub Menu Global System Definitions Global option G34 should be set to 115200 Network router is not serving IP addresses or the ST EG100 E is set to a static address Use a crossover cable to connect directly from the PC to the ST EG100 E This will require making...

Страница 43: ...uter settings the router must port forward port 2601 For ST EG100 E firmware updates port 21 must also be port forwarded through the router Cannot connect with ElkRP2 via Internet WAN If using a DDNS service any changes to the dynamic name may require time to propagate through the entire internet system Depending on the service this could even take 1 or 2 days Follow steps above for ElkRP2 connect...

Страница 44: ... Resolution correctly on the TCP IP tab of the M1XEP setup and that the DHCP configuration is correct for automatically obtaining the DNS information Verify the Rule to send email is written correctly Verify that ElkRP2 is disconnected when the triggering event occurs Ethernet Trouble Verify the ST EG100 E is connected to the M1 and enrolled ...

Отзывы: